C O M M I S S I O N I N G :
1.
Before operation, put a few drops of acid- and resin-free pneumatic oil in the air inlet of the tool.
2.
Before connecting the tool, clean the couplers and hoses by blasting them briefly with air. Make
sure hose and couplers have a sufficient diameter.
NOTE: THE DIAMETERS OF COMPRESSED AIR HOSES ARE USUALLY CHOSEN TOO SMALL,
NEVER TOO LARGE!
3.
The operating pressure measured under load at the tool air inlet should be 6.3 bar. A higher
pressure means greater wear and can cause damage to the tool. A fall in pressure to 5.5 bar
means extreme loss of power.
4.
Good air quality is vital for any pneumatic tool. The air must be clean, dry and lubricated. The
best solution is a complete maintenance unit comprising an air filter, regulator and oil-fog
lubricator which is no more than 6-8 m away from the tool. The oiler should be set to 3-6 drops
per minute (inspection glass). The length of the hose between tool and maintenance unit should
not exceed 8 m.
5.
We recommend using a central oiler unit for optimum tool lubrication. Up to 80% oil can be
saved, which also improves the quality of the air inhaled by the user of course, since no excess oil
is expelled to the air.
6.
The hammer mechanism of the impact screwdriver should be lubricated lightly after 60 working
hours at the latest. Too much grease will impair the power of the impact screwdriver since the
hammer mechanism will become sticky.
7.
If the tool is not to be used for a longer period, it must be lubricated thoroughly before storage.
Before re-use, please heed points 1 and 2.
8.
For changing the accessories, the drive screw should be blocked by using the locking tool.
9.
Before use, make sure accessory is fixed and centered onto the drive.