To use the 735r with other forms of sensor that contain either active high or active low
alarm contacts then short LK1 by fitting a jumper over the pins.
Selecting Active High or Active Low Alarm Contacts
With a jumper fitted to LK1, LK3 selects the polarity of the Alarm inputs.
LK3
Alarm input
Fitted
Normally Open or active Low
Not Fitted
Normally Closed or Active High
Programming
When using the 735r as a roller shutter detector or as a shock sensor then you may
program the detector's sensitivity to events. To enter programming mode short circuit
LK4 by fitting a jumper over both pins. The activity LED flashes continuously while the
transmitter is in programming mode. To leave programming mode remove the short circuit
from LK4 by fitting the jumper to one pin only. Note that you do not need to program the
735r when using it as a door contact.
Roller Shutter
When using the 735r with a roller shutter sensor you can program the transmitter to
transmit an alarm after a set number of open/close events on the roller shutter sensor. By
default the 735r will send an alarm after detecting six closures on the sensor. To change
this number: