Installation and Operation Manual
X-VA-MT3750C-eng
Part Number: 541B063AAG
®
TM
Brooks
Ar-Mite
MT 3750C
February, 2011
5
TM
Ar-Mite
Low Flow Armored Flowmeter
Ar-Mite
TM
Model MT 3750
Ar-Mite
TM
Model MT 3750
Metal Tube Flowmeter
Metal Tube Flowmeter
with Transmitter or Inductive Alarm

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Brooks Instrument Ar-Mite MT 3750

  • Seite 1 Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Ar-Mite Low Flow Armored Flowmeter Ar-Mite Model MT 3750 Ar-Mite Model MT 3750 Metal Tube Flowmeter Metal Tube Flowmeter with Transmitter or Inductive Alarm...
  • Seite 2 Read before proceeding! Brooks Instrument designs, manufactures and tests its products to meet many national and international standards. These products must be properly installed, operated and maintained to ensure they continue to operate within their normal specifications. The following instructions must be adhered to and integrated into your safety program when installing, operating and maintaining Brooks Instrument products.
  • Seite 3 We appreciate this opportunity to service your flow measurement and control requirements with a Brooks Instrument device. Every day, flow customers all over the world turn to Brooks Instrument for solutions to their gas and liquid low-flow applications. Brooks provides an array of flow measurement and control products for various industries from biopharmaceuticals, oil and gas, fuel cell research and chemicals, to medical devices, analytical instrumentation, semiconductor manufacturing, and more.
  • Seite 4 Installation and Operation Manual X-VA-MT3750C-eng Par Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Seite 5: Inhaltsverzeichnis

    Contents Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Paragraph Page Number Number Introduction Section 1 1-1 Description ............................1-1 1-2 Specifications ............................ 1-1 1-3 Optional Equipment ........................... 1-4 Installation Section 2 2-1 General .............................. 2-1 2-2 Receipt of Equipment ........................
  • Seite 6 Contents Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Figures Figure Page Number Number 1-1 Model MT 3750C with Reed Switch Alarm ..................1-5 1-2 Reed Switch Wiring Diagram ......................1-6 1-3 Model MT 3750C with Transmitter / Inductive Alarm ................. 1-7 1-4 Power Supply vs.
  • Seite 7: Description

    Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 1-1 Description The Brooks Ar-Mite is a reliable, low flow metal tube flowmeter with ® 316L stainless steel wetted parts. The magnetically coupled indicator provides a highly reliable method of indication.
  • Seite 8 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 Materials of Construction: Process Wetted 316L stainless steel (1.4404), Inconel 625, ® Titanium Grade II (Size 0 float only) Optional Monel K-500 (sizes 1-6 only) ®...
  • Seite 9 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 Table 1-1 Capacities Pressure Drop Flow Range (1,2) Water m 3 n/h In/h SCFH mBar Inches WC 0.021-0.21 0.08-0.8 3.9-39 0.15-1.5 0.034-0.34 0.13-1.3 5.6-56 0.21-2.1...
  • Seite 10: Optional Equipment

    Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 1-3 Optional Equipment Standard Needle Valves The standard needle or cartridge valves can be supplied integrally mounted to the inlet fitting of the instrument. The optional NRS needle valve, also integrally mounted to the inlet fitting, provides a greater number of turns affording precision control.
  • Seite 11 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 NEPSI: (China) GYJ05244 Ex ia IIC T6 per GB3836.1:2000; GB3836.2:2000 Non Incendive: ATEX: KEMA 02ATEX1127 II 3 GD T 75 EEx nA II T6 per EN60079-15: 2003;...
  • Seite 12 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 Reed Switch Alarm Two reed switches are installed in the alarm housing to provide signaling or switching functions when a preset flow value has been reached. The reed switches provide high, low or dual setpoints and latched output over the full range.
  • Seite 13 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 Figure 1-3 Model MT 3750C with Transmitter / Inductive Alarm Transmitter: 3750 The transmitter provides accurate magnet angle detection and conversion to a 4 - 20 mA industry standard output signal, based on the position of a float assembly in the flowmeter.
  • Seite 14 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 IECEx: KEM 06.0049 EX d IIC T6 per IEC 60079-0: 2004; IEC 60079-1: 2003 Intrinsic Safety: Functional parameters Power Supply 8-28 Vdc, Imax= 22 mA Entity Parameters: Ui = 30 V DC, Ii = 100 mA Pi = 750 mW...
  • Seite 15 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 Non Incendive Power Supply 8-28 Vdc, Imax= 22 mA Ambient Temperature: -30 C < Tamb < 65 ATEX: KEMA 01ATEX1035 II 3 GD T 70°C EEx nA II T6 per EN 60079-15: 2003;...
  • Seite 16 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 Figure 1-4 Power Supply vs. Maximum Load Resistance Figure 1-5 Transmitter Wiring Diagram Flow Controllers Flow controllers can be supplied integrally mounted to the inlet or outlet of the instrument.
  • Seite 17 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 [ INCH ] Figure 1-6 Dimensions for MT 3750C Flanged and Threaded Metal Tube Flowmeter with Indicator 1-11...
  • Seite 18 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 [ INCH ] Figure 1-7 Dimensions for MT 3750C Flanged and Threaded Connections with Transmitter or Inductive Alarm 1-12...
  • Seite 19 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 INCH [ MM ] Figure 1-8 Dimensions for MT 3750C Flanged and Threaded Connections with Reed Switch Alarm 1-13...
  • Seite 20 Section 1 Introduction Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG Brooks Ar-Mite MT 3750C ® February, 2011 Figure 1-9 Dimensions for MT 3750C Panel Mounting 1-14...
  • Seite 21: General

    If the packing case is damaged, the local carrier should be notified at once regarding his liability. A report should be submitted to your nearest Product Service Department. Brooks Instrument 407 W. Vine Street P.O. Box 903...
  • Seite 22: Return Shipment

    Instrument must have been purged in accordance with the following: All flow instruments returned to Brooks requires completion of Form RPR003-1, Brooks Instrument Decontamination Statement, along with a Material Safety Data Sheet (MSDS) for the fluid(s) used in the instrument.
  • Seite 23: Installation Of Flowmeter

    Section 2 Installation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 2-7 Installation of Flowmeter Recommended installation for Model MT 3750C is as follows: A. Carefully remove the covers from each end of the flowmeter. B.
  • Seite 24: Installation Of Reed Switch Alarm

    Section 2 Installation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 A. For intrinsically safe operation (recognized by a BLUE COVER), intrinsic safety barrier selection, cable parameters and power supply limits must be in accordance with the entity parameters shown on drawing.
  • Seite 25: Installation Of Transmitter

    Section 2 Installation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 both high alarm and low alarm applications. A circuit is completed by connecting wires to “Alarm In” and to either “HI” for high flow alarm or “LO”...
  • Seite 26 Section 2 Installation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Figure 2-3 Inductive Switch Wiring...
  • Seite 27 Section 2 Installation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Ref. No. 981Z985 Rev G pg. 1 Figure 2-4 Reed Switch Alarm Installation Using IS Barriers.
  • Seite 28 Section 2 Installation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Ref. No. 981Z985 Rev G pg. 2 Figure 2-5 Reed Switch Alarm Installation Using P&F Relay Unit. Note: CSA (US and Cananda). Approved installations refer to Figures 2-3 and 2-4.
  • Seite 29 Section 2 Installation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Figure 2-7 Transmitter Wiring Diagram for I.S. Systems...
  • Seite 30 Section 2 Installation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Figure 2-8 Transmitter Wiring Diagram for XP Systems 2-10...
  • Seite 31 Section 2 Installation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Figure 2-9 Transmitter Wiring Diagram 2-11...
  • Seite 32 Section 2 Installation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK 2-12...
  • Seite 33: Operating Procedure

    Section 3 Operation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 3-1 Operating Procedure After the flowmeter has been properly installed in the process, it is ready for operation. When initiating flow, slowly open the valve to avoid a flow surge.Bypass is a help in bringing the flow on smoothly.
  • Seite 34: Operation Of Reed Switch Alarm

    Section 3 Operation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 3-4 Operation of Reed Switch Alarm A.Start-up meter as described in Section 3-1 B.Note: The alarm flow ranges specified in Table 3-1 are for reference only.
  • Seite 35 Section 3 Operation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 C.Two jumper configurations allow simultaneous use of both the high and low alarm circuits. In the first of these configurations, an alarm is always active.
  • Seite 36 Section 3 Operation Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Figure 3-1 Reed Switch Alarm.
  • Seite 37: General

    Section 4 Maintenance Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 4-1 General CAUTION It is important that this device only be serviced by properly trained and qualified personel.
  • Seite 38: Service Information

    Section 4 Maintenance Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 4-2 Service Information 4-3 On Site Adjustment/Calibration The transmitter can be adjusted and/or calibrated with the help of a Windows 95/98 calibration program in combination with an applicable interface that can be plugged into any RS232 serial PC-port.
  • Seite 39: General

    Section 5 Parts List Installation and Operation Manual X-VA-MT 3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 5-1 General When ordering parts, please specify: Brooks Serial Number Model Number Part Description Quantity (Refer to Figure 5-1,and Tables 5-1, 5-2).
  • Seite 40 Section 5 Parts List Installation and Operation Manual X-VA-MT 3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Figure 5-1 Model MT 3750 Exploded View...
  • Seite 41 Section 5 Parts List Installation and Operation Manual X-VA-MT 3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Table 5-1 Model MT 3750 Recommended Spare Parts List (Refer to Figure 5-1) POS. QTY. Description O-ring size 015 Viton O-ring size 015 Buna O-ring size 015 EPDM O-ring size 015 Teflon...
  • Seite 42 Section 5 Parts List Installation and Operation Manual X-VA-MT 3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 Table 5-2 Model MT 3750 Indicator, Alarm and Transmitter Spare Parts List QTY. Description Scale Model MT3750 Indicator Cover MT3750 KFA relay Ex 1W, 220V/50Hz Intrinsically safe KFA relay Ex 2W, 220V/50Hz Intrinsically safe KFA relay Ex 1W, 110V/60Hz Intrinsically safe...
  • Seite 43: Essential Instructions

    Section A - Essential Instructions Installation and Operation Manual X-VA-MT3750C-eng Part Number:541B063AAG Brooks ® Ar-Mite MT 3750C February, 2011 Bulgarian Brooks Instrument Brooks Instrument. Brooks Instrument : (1) . (2) Brooks Instrument (PED) 0,5 bar (g) 25 mm 1" ( (PED).
  • Seite 44 P ed instalací si p e t te následující instrukce! Spole nost Brooks Instrument konstruuje, vyrábí a testuje tento produkt tak, aby splnil mnoho národních a mezinárodních standard . P ístroje musí být ádn nainstalovány, používány a udržovány tak, aby byl zajišt n jejich nep etržitý provoz v rámci normálních technických specifikací. Musíte dodržovat následující...
  • Seite 45 Section A - Essential Instructions Installation and Operation Manual X-VA-MT3750C-eng Part Number:541B063AAG Brooks ® Ar-Mite MT 3750C February, 2011 Dansk Grundlæggende vejledninger Læs disse før anvendelse! Brooks Instruments designer, fremstiller og afprøver sine produkter således, at de tilpasser sig både de indenrigs og internationale standarder. Disse udstyr bør installeres, bruges og repareres omhyggeligt, så...
  • Seite 46 Lees ze voordat u verder gaat! Brooks Instrument ontwerpt, produceert en test haar producten zodanig dat ze voldoen aan vele nationale en internationale normen. Deze producten moeten correct worden geïnstalleerd, bediend en onderhouden zodat ze binnen hun normale specificaties blijven werken. De volgende instructies moeten worden toegevoegd aan en geïntegreerd in uw veiligheidsprogramma als u producten van Brooks Instrument installeert, bedient en onderhoudt.
  • Seite 47 Olulised juhised Enne kasutamist lugege hoolikalt läbi! Brooks Instrument konstrueerib, valmistab ja katsetab oma tooteid selliselt, et need vastaksid paljude erinevate riiklike ja rahvusvaheliste standardite nõuetele. Ainult nõuetekohane paigaldamine, kasutamine ja hooldamine tagab toodete katkematu talitluse tavaspetsifikatsiooni raames. Brooks Instrument'i toodete paigaldamisel, kasutamisel ja hooldamisel tuleb täita alljärgnevaid juhiseid ja integreerida need asjakohasesse ohutusprogrammi.
  • Seite 48 Perusohjeet Lue ensin ohjeet huolellisesti! Brooks Instrument suunnittelee, valmistaa ja testaa laitteensa vastaamaan useimpien kotimaisten ja kansainvälisten standardien vaatimuksia. Tuotteet tulee asentaa, käyttää ja huoltaa käyttöohjeiden mukaan jotta niiden toimivuus taataan. Brooks Instrumentin laitteiden asennuksessa, käytössä ja huollossa on noudatettava soveltuvia määräyksiä ja ohjeita, lisäksi mainitut ohjeet on huomioitava työsuojelun ohjeistuksessa.
  • Seite 49 Brooks Instrument et que des personnes qualifiées effectuent le remplacement. Les pièces et procédures non autorisées peuvent porter atteinte au fonctionnement du produit et mettre en péril la sécurité de votre procédé. Les remplacements par des pièces d’apparence similaire peuvent entraîner des incendies, des risques électriques ou un mauvais fonctionnement.
  • Seite 50 Bitte zuerst lesen! Brooks Instrument entwickelt, produziert und testet seine Produkte derart, dass sie viele nationale und internationale Standards erfüllen. Nur bei korrektem Einbau sowie richtiger Bedienung und Wartung dieser Produkte ist ein Betrieb unter Einhaltung der Standardvorgaben sichergestellt. Die folgenden Anweisungen müssen eingehalten werden und in Ihr Sicherheitsprogramm integriert werden, wenn Sie Brooks Produkte installieren, bedienen und warten.
  • Seite 51 Section A - Essential Instructions Installation and Operation Manual X-VA-MT3750C-eng Part Number:541B063AAG Brooks ® Ar-Mite MT 3750C February, 2011 Greek Brooks Instrument Brooks Instrument. ’ Brooks Instrument. : (1) . (2) Brooks Instrument. (PED) 0,5 bar (g) 25 mm (PED).
  • Seite 52 El ször olvassa el ezeket! A Brooks Instrument olyan módon tervezi, gyártja és teszteli termékeit, hogy azok megfeleljenek számos belföldi és nemzetközi szabványnak. Ezeket a berendezéseket megfelel en kell telepíteni, üzemeltetni és karbantartani ahhoz, hogy mindenképpen a normál m ködési tartományuknak megfelel en üzemelhessenek.
  • Seite 53 Leggerle subito! La Brooks Instrument progetta, fabbrica e collauda i propri prodotti in maniera tale che siano conformi ai vari standard nazionali ed internazionali. Tali apparecchiature devono essere installate, messe in esercizio e tenute in manutenzione in maniera adeguata affinché operino in conformità alle loro normali specifiche di funzionamento.
  • Seite 54 P rliecinieties par to, lai pirms instrumenta tehnisk s apkopes b tu likvid ts procesa l nijas spiediens. Ja ir nepieciešams veikt k du da u nomai u, nodrošiniet, lai tiktu izmantotas „Brooks Instrument” nor d t s da as un da u nomai u veiktu kvalific ts person ls. Neat autu da u un proced ru izmantošana var ietekm s ražojuma sniegumu un samazin t procesa droš...
  • Seite 55 25 mm arba 1 colio ar mažesni matuokliai atitinka tinkam inžinerijos praktik (SEP). Europoje taikomi elektromagnetinio suderinamumo (EMC) reikalavimai CE ženklu pažym ta „Brooks Instrument“ (elektrin / elektronin ) ranga buvo s kmingai išbandyta pagal elektromagnetinio suderinamumo reikalavimus (EMC direktyv 2004/108/EC (89/336/EEB)).
  • Seite 56: Ostrze Enie

    / lub uszkodzenia sprz tu. Je eli jakie zalecenia w instrukcji obs ugi urz dzenia s niezrozumia e, prosimy o skontaktowanie si z przedstawicielem firmy Brooks Instrument, aby wyja ni problem.
  • Seite 57 Antes de proceder, leia-as! A Brooks Instrument projecta, fabrica e testa os seus produtos de forma a que os mesmos satisfaçam numerosas normas nacionais e internacionais. Os equipamentos devem ser instalados, explorados e mantidos de maneira adequada, e devem funcionar de acordo com a sua gama de utilização. Durante a instalação, exploração e manutenção dos equipamentos da Brooks Instrument, as instruções seguintes devem ser observadas e integradas no programa de...
  • Seite 58 În m sura în care indica iile c r ii ma inii nu sunt suficient de l muritoare, lua i leg tura cu reprezentantul Brooks Instrument pentru clarificarea problemei. P stra i toate avertismentele, avizele i instruc iunile livrate odat cu instala ia sau inscrip ionate pe aceasta.
  • Seite 59 Pre íta pred inštaláciou! Brooks Instrument svoje výrobky projektuje, vyrába a testuje takým spôsobom, aby tieto vyhoveli domácim aj medzinárodným normám. Tieto zariadenia je potrebné predpísaným spôsobom inštalova , prevádzkova a udržiava , na zabezpe enie ich spo ahlivej a normálnej prevádzky v celom pracovnom rozsahu.
  • Seite 60 Najprej preberite jih Brooks Instrument tako konstruira, izdeluje in terstira svoje izdelke, da oni ustrezajo številnim doma im in mednarodnim standardom. Te naprave se morajo ustrezno instalirati, koristiti in vzdrževati, da vsekakor delajo ustrezno normalnom podro ju funkcioniranja. Naslednjih navodil se mora držati in potrebno je vgraditi v program varstva pri delu pri instaliranju, koriš...
  • Seite 61 ¡Léalos primero! El Brooks Instrument proyecta, fabrica y prueba sus productos de manera que éstos respondan a numerosas normas nacionales e internacionales. Dichas instalaciones deben ser emplazadas, operadas y mantenidas adecuadamente, para que puedan marchar de todas formas en conformidad con el alcance normal de funcionamiento.
  • Seite 62 Läs detta innan du fortsätter ! Brooks Instrument konstruerar, tillverkar och testar sina produkter med syfte att uppfylla alla nationella och internationella standarder. Dessa produkter måste installeras på rätt sätt, handhas och underhållas för att de skall fungera kontinuerligt enligt deras normala specifikation. De följande anvisningarna bör följas och integreras till Ert säkerhetsprogram varje gång när Brooks Instruments produkter installeras, handhas och underhålls.
  • Seite 63 Installation and Operation Manual X-VA-MT3750C-eng Part Number: 541B063AAG ® Brooks Ar-Mite MT 3750C February, 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Seite 64 Europe +31 (0) 318 549 290 Asia +81 (0) 3 5633 7100 Due to Brooks Instrument's commitment to continuous improvement of our products, all specifications are subject to change without notice. TRADEMARKS Ar-Mite ............Brooks Instrument, LLC NRS .............. Brooks Instrument, LLC Brooks ............

Diese Anleitung auch für:

Ar-mite mt3750

Inhaltsverzeichnis