Inhaltszusammenfassung für Brooks Instrument MT3809G

  • Seite 1 Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 ® Brooks Models MT3809G and MT3810G Metal Tube Variable Area Flowmeters Model MT3809G General Purpose Housing Model MT3809G Model MT3809G Explosion Proof Housing Intrinsically Safe Housing...
  • Seite 2 Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013...
  • Seite 3 We appreciate this opportunity to service your flow measurement and control requirements with a Brooks Instrument device. Every day, flow customers all over the world turn to Brooks Instrument for solutions to their gas and liquid low-flow applications. Brooks provides an array of flow measurement and control products for various industries from biopharmaceuticals, oil and gas, fuel cell research and chemicals, to medical devices, analytical instrumentation, semiconductor manufacturing, and more.
  • Seite 4 Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Seite 5: Inhaltsverzeichnis

    Installation and Operation Manual Contents X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Paragraph Page Number Number Section 1 Introduction Description ............................ 1-1 Design Features ..........................1-1 Meter Specifications ........................1-1 Optional Accessories ........................1-9 Optional Electronic Equipment ...................... 1-9 1-5-1 Transmitter with or without Alarms Display and Pulse Output ............
  • Seite 6 Exploded View, Model MT3809G and MT3810G - Gas Service ........... 4-5 Exploded View, Model MT3809G and MT3810G - Liquid Service ..........4-6 Exploded View, Model MT3809G, Size 15 (Gas or Liquid Service Only) ........4-7 Exploded View, Model MT3809G, Size 16 (Liquid Service Only) ..........4-7 Meter Float Replacement &...
  • Seite 7: Section 1 Introduction

    Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 1-1 Descripton The Brooks Models MT3809 and MT3810 are rugged, all metal ® flowmeters offering reliable operation based on the variable area principle.
  • Seite 8 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Table 1-1 Specifications Meter MT3809 MT3809 MT3809 MT3809 MT3809 TFE Lined TFE Lined TFE Lined TFE Lined TFE Lined MT3810 MT3810 MT3810 MT3810...
  • Seite 9 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Table 1-2A Model MT3809/MT3810 Capacities, Pressure Drop and Viscosity Immunity Ceiling Table 1-2B Model MT3809 ETFE Lined Capacities, Pressure Drop and Viscosity Immunity Ceiling...
  • Seite 10 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Table 1-3A Model MT3809/MT3810 Pressure Ratings, Flanged Table 1-3B Model MT3809/MT3810 Pressure Ratings, NPT Female...
  • Seite 11 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Table 1-3C Model MT3809/MT3810 Pressure Ratings, NPT Male Table 1-4 Temperature Cut-off Tables...
  • Seite 12 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-1 Model MT3809 and MT3810 Dimensional Drawings (mm/in) and Weights (kg/lbs) - General Purpose Housing...
  • Seite 13 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-2 Model MT3809 and MT3810 Dimensional Drawings (mm/in) and Weights (kg/lbs) - Intrinsically Safe Housing...
  • Seite 14 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-3 Model MT3809 and MT3810 Dimensional Drawings (mm/in) and Weights (kg/lbs) - Explosion Proof Housing...
  • Seite 15: Optional Accessories

    Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 1-4 Optional Accessories Needle valves and flow controllers may be externally piped into the inlet or outlet side of the instrument. Needle valves can be supplied up to size 12 1-1/2"...
  • Seite 16 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Appr Approvals P Appr ovals P ovals P ovals Pending ending ending ending Appr Appr ovals P ending A A A A A TEX...
  • Seite 17: Inductive Alarms

    Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 1-5-2 Inductive Alarms Design Featur Design Featur Design Featur Design Featur Design Features es es es es • 1 or 2 normally open inductive limit switches •...
  • Seite 18 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-4A Wiring Diagram, Model MT3809 Transmitter, 4-20 mA 1-12...
  • Seite 19 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-4B Wiring Diagram, Model MT3809 Transmitter, 4-20 mA 1-13...
  • Seite 20 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-5A Wiring Diagram, Model MT3809, 4-20 mA Transmitter, One or Two Optical Alarms and PPU 1-14...
  • Seite 21 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-5B Wiring Diagram, Model MT3809, 4-20 mA Transmitter, One or Two Optical Alarms and PPU 1-15...
  • Seite 22 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-6A Wiring Diagram, Model MT3809 Explosion Proof, 4-20 mA Transmitter with Inductive Alarms, Optical Alarms and PPU 1-16...
  • Seite 23 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-6B Wiring Diagram, Model MT3809 Explosion Proof, 4-20 mA Transmitter with Inductive Alarms, Optical Alarms and PPU 1-17...
  • Seite 24 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-7A Wiring Diagram, Model MT3809, One or Two Inductive Alarms 1-18...
  • Seite 25 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-7B Wiring Diagram, Model MT3809, One or Two Inductive Alarms 1-19...
  • Seite 26 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-8A Wiring Diagram, Model MT3809, 4-20 mA Transmitter, One or Two Inductive Alarms 1-20...
  • Seite 27 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 1-8B Wiring Diagram, Model MT3809, 4-20 mA Transmitter, One or Two Inductive Alarms 1-21...
  • Seite 28 Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Loop Voltage vs. Load Resistance 1050 Loop Resistance (maximum ohms) = 30 X voltage + 16 1000 Loop Voltage Note: load resistance should also include I.S. barrier resistance. When using HART communicator the minimum load resistance is 250 ohms.
  • Seite 29: Microprocessor Transmitter With Or Without Inductive Alarms

    Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 1-5-3 Microprocessor Transmitter with or without Inductive Alarms This combined system provides both the sophistication of the microprocessor along with the simplicity of one or two switch inductive alarms.
  • Seite 30: Inductive Alarm Switches

    Installation and Operation Manual Section 1 Introduction X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 1-5-4 Inductive Alarm Switches Design Features * 1 or 2 normally open inductive limit switches * Optional intrinsically safe power supply/amplifier/relay unit * For low or high limit signalling/switching...
  • Seite 31: Section 2 Installation

    2-3 Recommended Storage Practices If intermediate or long-term storage is required for equipment, as supplied by Brooks Instrument, it is recommended that the equipment be stored in accordance with the following: a. Within the original shipping container. b. Stored in a sheltered area, preferably a warm, dry, heated warehouse.
  • Seite 32: Return Shipment

    Instrument must have been purged in accordance with the following: All flow instruments returned to Brooks requires completion of Form RPR003-1, Brooks Instrument Decontamination Statement, along with a Material Safety Data Sheet (MSDS) for the fluid(s) used in the instrument. Failure to provide this information will delay processing by Brooks personnel.
  • Seite 33 Installation and Operation Manual Section 2 Installation X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Recommended installation for Models MT3809 and MT3810 is as follows: a. Carefully remove the covers from each end of the flowmeter. The float may be fixed to avoid damage during transport.
  • Seite 34: Installation And Maximum Torques Of Model Mt3809 Etfe

    Section 2 Installation Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 2-5-1 Installation and Maximum Torques of Model MT3809 ETFE MAXIMUM TORQUES MODEL MT3809 ETFE Please refer to Table 2-1 below. • Select bolts and gaskets (customer supply) in keeping with the flange pressure rating or the operating pressure.
  • Seite 35 Section 2 Installation X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Range parameter is set at 500 and the AO Lo-Range is set at 100. Like other common parameters, the AO Hi-Range and AO Lo-Range can be set by Brooks prior to shipment.
  • Seite 36 Section 2 Installation Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 6. After installation and powering of the loop, the transmitter must be zeroed, both electrically and mechanically. This operation will compensate for any stray magnetic effects in the vicinity of the transmitter. Flow must be verified to be zero when the zero function is momentarily activated.
  • Seite 37: Installation Of The Model Mt3809 Flowmeter With A Transmitter With Inductive Alarms (1 Or 2 Switches)

    Section 2 Installation X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 4. The shielded cable must be used for hook up. The shield should be connected to chassis ground at the transmitter end and should be taped up and not connected at the receiver end.
  • Seite 38: Installation Of The Model Mt3809 Flowmeter With Transmitter And Digital Display And Inductive Alarms

    Section 2 Installation Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 2. Intrinsically safe installations require the use of relay isolators for the alarms and a barrier for the transmitter, if equipped. Power supply limits and cable parameters must be as shown in the installation diagram.
  • Seite 39: Section 3 Operation

    Installation and Operation Manual Section 3 Operation X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 3-1 Pre-Start Check After the flowmeter has been properly installed in the process, it is ready for operation. When initiating flow, slowly open the valve to avoid a flow surge.
  • Seite 40: Operation Of The Model Mt3809 Flowmeter With A Transmitter With Or Without Optional Alarms And Pulse Output For Totalization

    Section 3 Operation Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 3-3 Operation of the Model MT3809 Flowmeter with a Transmitter with or without Optional Alarms and Pulse Output for Totalization * Start-up the meter as described in Section 3-2.
  • Seite 41 Installation and Operation Manual Section 3 Operation X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 3-1 Model MT3809 Electronics Basic Setup Menu Tree...
  • Seite 42 Section 3 Operation Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 3-2 Model MT3809 Electronics Detailed Setup Menu Tree...
  • Seite 43 Section 3 Operation X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 The alarms may be set at the minimum and maximum flow rate or at any other preferred high and low limits. The units of measure of the alarm limits are the same units of measure as the process variable itself.
  • Seite 44 Section 3 Operation Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 3-3 Model MT3809 Electronics LOI Chart Menu...
  • Seite 45: Operation Of The Model Mt3809 Flowmeter With A Transmitter And Inductive Alarms (1 Or 2 Switches)

    Installation and Operation Manual Section 3 Operation X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 3-4 Operation of the Model MT3809 Flowmeter with a Transmitter and Inductive Alarms (1 or 2 switches) a. Start-up the meter as described in Section 3-2.
  • Seite 46 Section 3 Operation Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Seite 47: Section 4 Maintenance

    Installation and Operation Manual Section 4 Maintenance X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 4-1 General Service Information...
  • Seite 48: Meter Float Replacement And Cleaning (Mt3809 & Mt3810)

    Section 4 Maintenance Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 WARNING If this equipment is not properly serviced, serious personal injury and/or damage to the equipment can result from potentially high operating pressures. Process line pressure should be removed prior to servicing.
  • Seite 49 Installation and Operation Manual Section 4 Maintenance X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 c. Size 8 (½") flanged, gas service 1. Remove the meter from the process line and lay the meter horizontal on a table.
  • Seite 50 Section 4 Maintenance Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 4. Reassemble by inserting the float assembly inside the conical taper (as well as the spacer bushing, size 16 only). Then insert the complete float assembly into the bottom of the meter.
  • Seite 51 Installation and Operation Manual Section 4 Maintenance X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 4-1 Exploded View, Model MT3809G and MT3810G - Gas Service...
  • Seite 52 Section 4 Maintenance Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 4-2 Exploded View, Model MT3809G and MT3810G - Liquid Service...
  • Seite 53 Installation and Operation Manual Section 4 Maintenance X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Figure 4-3 Exploded View, Model MT3809G, Size 15 (Gas or Liquid Service Only) Figure 4-4 Exploded View, Model MT3809G, Size 16 (Liquid Service Only)
  • Seite 54: Meter Float Replacement And Cleaning (Mt3809 Etfe Option)

    Section 4 Maintenance Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 4-3 Meter Float Replacement and Cleaning (MT3809 ETFE Option) (Refer to Figure 4-5) Flanged connections, all sizes, liquid or gas a. Remove the meter from the process line and lay the meter horizontal on a table.
  • Seite 55 Installation and Operation Manual Section 4 Maintenance X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 Sizes 7 & 8 Sizes 10, 12 & 13 Figure 4-5 Meter Float Replacement & Cleaning (ETFE Option) k. Replace the scale and tighten two clamping screws. Make sure that the alarm switch wires do not interfere with the alarm cam.
  • Seite 56: Transmitter Replacement With Inductive Alarms

    Section 4 Maintenance Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 4-7 Transmitter Replacement with Inductive Alarms The transmitter is a self contained unit matched specifically to the associated flowmeter. If there is a need to replace, please contact your nearest authorized Brooks service representative.
  • Seite 57: Essential Instructions

    Section A Essential Instructions Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG September, 2013 Models MT3809G & MT3810G Bulgarian Brooks Instrument Brooks Instrument. Brooks Instrument : (1) . (2) Brooks Instrument (PED) 0,5 bar (g) 25 mm 1" ( (PED).
  • Seite 58: Základní Instrukce

    P ed instalací si p e t te následující instrukce! Spole nost Brooks Instrument konstruuje, vyrábí a testuje tento produkt tak, aby splnil mnoho národních a mezinárodních standard . P ístroje musí být ádn nainstalovány, používány a udržovány tak, aby byl zajišt n jejich nep etržitý provoz v rámci normálních technických specifikací. Musíte dodržovat následující...
  • Seite 59 Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG September, 2013 Models MT3809G & MT3810G Dansk Grundlæggende vejledninger Læs disse før anvendelse! Brooks Instruments designer, fremstiller og afprøver sine produkter således, at de tilpasser sig både de indenrigs og internationale standarder. Disse udstyr bør installeres, bruges og repareres omhyggeligt, så...
  • Seite 60 Lees ze voordat u verder gaat! Brooks Instrument ontwerpt, produceert en test haar producten zodanig dat ze voldoen aan vele nationale en internationale normen. Deze producten moeten correct worden geïnstalleerd, bediend en onderhouden zodat ze binnen hun normale specificaties blijven werken. De volgende instructies moeten worden toegevoegd aan en geïntegreerd in uw veiligheidsprogramma als u producten van Brooks Instrument installeert, bedient en onderhoudt.
  • Seite 61 Olulised juhised Enne kasutamist lugege hoolikalt läbi! Brooks Instrument konstrueerib, valmistab ja katsetab oma tooteid selliselt, et need vastaksid paljude erinevate riiklike ja rahvusvaheliste standardite nõuetele. Ainult nõuetekohane paigaldamine, kasutamine ja hooldamine tagab toodete katkematu talitluse tavaspetsifikatsiooni raames. Brooks Instrument'i toodete paigaldamisel, kasutamisel ja hooldamisel tuleb täita alljärgnevaid juhiseid ja integreerida need asjakohasesse ohutusprogrammi.
  • Seite 62 Perusohjeet Lue ensin ohjeet huolellisesti! Brooks Instrument suunnittelee, valmistaa ja testaa laitteensa vastaamaan useimpien kotimaisten ja kansainvälisten standardien vaatimuksia. Tuotteet tulee asentaa, käyttää ja huoltaa käyttöohjeiden mukaan jotta niiden toimivuus taataan. Brooks Instrumentin laitteiden asennuksessa, käytössä ja huollossa on noudatettava soveltuvia määräyksiä ja ohjeita, lisäksi mainitut ohjeet on huomioitava työsuojelun ohjeistuksessa.
  • Seite 63: A Lire Avant De Commencer

    Brooks Instrument et que des personnes qualifiées effectuent le remplacement. Les pièces et procédures non autorisées peuvent porter atteinte au fonctionnement du produit et mettre en péril la sécurité de votre procédé. Les remplacements par des pièces d’apparence similaire peuvent entraîner des incendies, des risques électriques ou un mauvais fonctionnement.
  • Seite 64 Bitte zuerst lesen! Brooks Instrument entwickelt, produziert und testet seine Produkte derart, dass sie viele nationale und internationale Standards erfüllen. Nur bei korrektem Einbau sowie richtiger Bedienung und Wartung dieser Produkte ist ein Betrieb unter Einhaltung der Standardvorgaben sichergestellt. Die folgenden Anweisungen müssen eingehalten werden und in Ihr Sicherheitsprogramm integriert werden, wenn Sie Brooks Produkte installieren, bedienen und warten.
  • Seite 65 Section A Essential Instructions Installation and Operation Manual X-VA-MT3809G-MT3810G-eng Part Number: 541B182AAG September, 2013 Models MT3809G & MT3810G Greek Brooks Instrument Brooks Instrument. ’ Brooks Instrument. : (1) . (2) Brooks Instrument. (PED) 0,5 bar (g) 25 mm (PED). PED.
  • Seite 66 üzemeltetni és karbantartani ahhoz, hogy mindenképpen a normál m ködési tartományuknak megfelel en üzemelhessenek. Az alábbi utasításokat be kell tartani, és be kell építeni a munkavédelmi programba a Brooks Instrument termékeinek telepítése, üzemeltetése és karbantartása során.
  • Seite 67 Leggerle subito! La Brooks Instrument progetta, fabbrica e collauda i propri prodotti in maniera tale che siano conformi ai vari standard nazionali ed internazionali. Tali apparecchiature devono essere installate, messe in esercizio e tenute in manutenzione in maniera adeguata affinché operino in conformità alle loro normali specifiche di funzionamento.
  • Seite 68 P rliecinieties par to, lai pirms instrumenta tehnisk s apkopes b tu likvid ts procesa l nijas spiediens. Ja ir nepieciešams veikt k du da u nomai u, nodrošiniet, lai tiktu izmantotas „Brooks Instrument” nor d t s da as un da u nomai u veiktu kvalific ts person ls. Neat autu da u un proced ru izmantošana var ietekm s ražojuma sniegumu un samazin t procesa droš...
  • Seite 69 25 mm arba 1 colio ar mažesni matuokliai atitinka tinkam inžinerijos praktik (SEP). Europoje taikomi elektromagnetinio suderinamumo (EMC) reikalavimai CE ženklu pažym ta „Brooks Instrument“ (elektrin / elektronin ) ranga buvo s kmingai išbandyta pagal elektromagnetinio suderinamumo reikalavimus (EMC direktyv 2004/108/EC).
  • Seite 70 Urz dzenia pomiarowe o wielko ci 25 mm lub 1 cala lub mniejsze podlegaj zaleceniom „Uznanej Praktyki In ynierskiej” (SEP). Europejska dyrektywa dotycz ca kompatybilno ci elektromagnetycznej (EMC) Urz dzenia elektryczne / elektroniczne firmy Brooks Instrument posiadaj ce oznaczenie CE, przesz y pozytywnie testy pod k tem spe niania przez nich wymogów kompatybilno ci elektromagnetycznej (Dyrektywa EMC 2004/108/EC).
  • Seite 71 Ler antes de proceder! A Brooks Instrument projecta, fabrica e testa os seus produtos de forma a satisfazer numerosas normas nacionais e internacionais. Estes equipamentos devem ser instalados, utilizados e mantidos de forma adequada, e devem funcionar dentro da sua gama de utilização. As instruções seguintes devem ser, durante a instalação, uso e/ou manutenção dos equipamentos da Brooks Instrument, apreendidas e integradas no plano de...
  • Seite 72 În m sura în care indica iile c r ii ma inii nu sunt suficient de l muritoare, lua i leg tura cu reprezentantul Brooks Instrument pentru clarificarea problemei.
  • Seite 73 Pre íta pred inštaláciou! Brooks Instrument svoje výrobky projektuje, vyrába a testuje takým spôsobom, aby tieto vyhoveli domácim aj medzinárodným normám. Tieto zariadenia je potrebné predpísaným spôsobom inštalova , prevádzkova a udržiava , na zabezpe enie ich spo ahlivej a normálnej prevádzky v celom pracovnom rozsahu.
  • Seite 74 Najprej preberite jih Brooks Instrument tako konstruira, izdeluje in terstira svoje izdelke, da oni ustrezajo številnim doma im in mednarodnim standardom. Te naprave se morajo ustrezno instalirati, koristiti in vzdrževati, da vsekakor delajo ustrezno normalnom podro ju funkcioniranja. Naslednjih navodil se mora držati in potrebno je vgraditi v program varstva pri delu pri instaliranju, koriš...
  • Seite 75 ¡Léalos primero! El Brooks Instrument proyecta, fabrica y prueba sus productos de manera que éstos respondan a numerosas normas nacionales e internacionales. Dichas instalaciones deben ser emplazadas, operadas y mantenidas adecuadamente, para que puedan marchar de todas formas en conformidad con el alcance normal de funcionamiento.
  • Seite 76 Läs detta innan du fortsätter ! Brooks Instrument konstruerar, tillverkar och testar sina produkter med syfte att uppfylla alla nationella och internationella standarder. Dessa produkter måste installeras på rätt sätt, handhas och underhållas för att de skall fungera kontinuerligt enligt deras normala specifikation. De följande anvisningarna bör följas och integreras till Ert säkerhetsprogram varje gång när Brooks Instruments produkter installeras, handhas och underhålls.
  • Seite 77 Installation and Operation Manual X-VA-MT3809G-MT3810G Part Number: 541B182AAG Models MT3809G & MT3810G September, 2013 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Seite 78: Trademarks

    Europe +31 (0) 318 549 290 Asia +81 (0) 3 5633 7100 Due to Brooks Instrument's commitment to continuous improvement of our products, all specifications are subject to change without notice. TRADEMARKS Brooks ..................... .Brooks Instrument, LLC HART ..................HART Communications Foundation...

Diese Anleitung auch für:

Mt3810gAr-mite mt3750Ar-mite mt3750c