Technical Data - Weidmuller MCZ CCC 0-Serie Bedienungsanleitung

Analoger messwandler 0/0 ... 20 ma im klemmengehäuse
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
9.

Technical Data

Input
Input voltage
Operating current
Voltage drop
Input overload capacity
Output
Load
Adjustment period (T99)
Residual ripple
General data
Chopper frequency
Transmission errors
Temperature effect
Test voltage
Input / output
CEM
2)
Ambient temperature
Operation
Storage
The cable lengths must not exceed 30 m.
1) Medium TC in the specified operating temperature
range of -25 °C ... +60 °C.
2) Valid for 4 ... 20 mA; minor deviations are possible
during interferences.
22
0 ... 20 mA
max. 15 V
< 100 µA
2.5 ... 3 V @ 20 mA
max. 50 mA, 15 V
0 ... 20 mA, max. 10 V
500 Ω
approx. 5 ms for a load of
500 Ω
< 10 mV
approx. 200 kHz
< 0.1 % of end value +
0.05 % of measured value
/ 100 Ω load
50 ppm/K from measured
1)
value for a load of 0 Ω
510 V CA, 50 Hz
EMC directive
EN 61326, EN 61326/A1
-25 °C ... +60 °C
-40 °C ... +85 °C
eff