11. Models may be poured after 15 minutes when using Correct Plus Fast Set
Impression Material and after 30 minutes when using Correct Plus
Hydrophilic Impression Material.
Putty:
1. Using the scoops provided, dispense equal quantities of base and catalyst.
2. Mix with a stiff spatula (or knead with fingers) until a uniform, streak-
free color is achieved, usually less than 45 seconds. Optimal performance
requires a ratio of 1:1; slight variations in the relative amounts of base or
catalyst with neither increase nor decrease work or set times.
NOTE: Never mismatch batch sets of base & catalyst, as unpredictable work
and/or set times may result. Do not use latex gloves to mix putty. Wash hands
thoroughly before mixing putty by hand.
Material
Description
Correct Plus
Hydrophilic
Impression
Material – Auto
Mix Cartridges
Correct Plus
Hydrophilic
Impression
Material – Putty
Correct Plus Fast
Set Impression
Material – Auto
Mix Cartridges
Correct Plus Bite
Superfast
*These times may vary based on storage conditions, temperature, humidity,
and age of product.
Important Notes:
Hemostatic agents and retraction cords that contain ferric sulfates may
inhibit the set of impression material. Before taking impression, rinse the
preparation site thoroughly with water to remove any residual
contaminants.
Due to its rigidity, use caution when using Correct Plus and Correct Plus
Fast Set Auto-Mix Putty on periodontally involved teeth or on bridges
unless severe undercuts below the pontics are blocked out.
4
Minimum
Working Time*
1 minute
1 minute
45 seconds
15 seconds
Maximum Intra
Oral Setting Time*
(from initial mix)
4 minutes and 30
seconds
4 minutes and 30
seconds
2 minutes and 30
seconds
1 minute and 15
seconds