HIDDEN AND ADVANCED FEATURES
Feature
PROGRAMMABLE SENSOR
OVERRIDE
CYCLE AND SOAK
DELAY BETWEEN STATIONS
HIDE PROGRAMS
CLIK-DELAY
TOTAL RUN TIME
EASY RETRIEVE
TOTAL RESET
QUICK CHECK

TROUBLESHOOTING GUIDE

Display
DISPLAY SHOWS "ERR" WITH
NUMBER
DISPLAY SHOWS P "ERR"
DISPLAY SHOWS SP "ERR"
DISPLAY SHOWS WATERING BUT
NO WATER IS OCCURRING
FROZEN OR GARBLED DISPLAY
RAIN SENSOR DOES NOT STOP
IRRIGATION
CONTROLLER SEEMS TO WATER
CONTINUOUSLY
When this symbol is shown, the controller is now managed online with Hydrawise software and the controller dial and buttons are inoperable. Set schedules, suspend zones, configure
sensors, and more with the Hydrawise application. Leave dial in RUN position to continue Hydrawise programming schedule.
?
For troubleshooting information:
https:/ /hunter.direct/X2help
© 2019 Hunter Industries Inc. Hunter, the Hunter logo, and all other trademarks are property of Hunter Industries, registered in the U.S. and other countries. | hunterindustries.com
Where Found
Hold – and turn to Start Times
+
Hold
and turn to Run Times. Enter Cycle, press
PRG to set Soak
Hold – and turn to Run Times
Hold
and turn to Water Days
Hold + and turn to Off
Turn to Run Times. Press ◄ when station 1 is shown,
PRG to select other programs.
Hold + and PRG to Save. Hold – and PRG to Restore Saves all program information to restore at a later time.
Hold PRG and press RESET button.
+, –, ◄, ► together, then +
Possible Cause
Short in field wiring, or bad solenoid.
Short in Pump/Master Valve wiring or solenoid.
SmartPort
error. Electrical noise is present near
®
connection to remote or other SmartPort device.
Problem in field wiring. Problem with solenoids. No
water pressure to system.
Power surge
Jumper wire is not removed. Sensor switch in
BYPASS position.
Too many start times.
NOTE: If the supply cord is damaged, it must be replaced by the manufacturer
or service agent or a similarly qualified person to avoid hazard.
Description
Sets individual stations to ignore sensor shutdowns. Select stations with ◄ or ►, (use +/
to OFF to ignore sensor.
Sets max time a station can run at once, and minimum time it must wait before another cycle.
Divides run time into segments to prevent runoff.
Inserts a delay (seconds or minutes) between stations in a run time, for slow valves or
recharging tanks.
Use +/
to change from 4 to 1 to hide extra programs. 1 will show only program A,
start time 1. 4 will show all programs and start times.
Set number of days for watering to remain off, after sensor has been activated and restored.
Calculates and displays total of all run times in a program start time.
Returns to factory defaults and erases watering schedule and settings.
Checks all stations for wiring problems.
Solutions
Check field wiring and valve solenoid. Press any button to clear ERR message.
Check wiring and solenoid at P/MV. Check specifications for Pump Start Relay.
Move connections away from sources of electrical noise.
Check field wiring (voltmeter). Check valve solenoid(s). Verify water source is open.
Reset controller.
Remove jumper wire on SEN terminals. Set sensor switch to Active position.
One Start Time operates all stations in a program. Remove unnecessary start times.
) to change
RC-103 - QG -US 9/19