MODELOS Y CARACTERÍSTICAS
900BR-V
Barrera electromecánica irreversible de hasta
900BR-24
Barrera electromecánica irreversible de hasta 4 m. de longitud.
DATOS TÉCNICOS
ALIMENTACION
POTENCIA ABSORBIDA
REVOLUCIONES MOTOR
ABSORCION MOTOR
CONDENSADOR
TIEMPO DE ABERTURA
LONGITUD MAX. ASTA
SERVICIO TEMPORANEO
TEMPERATURA DE OPERACION
PESO
4
m. de longitud. 4 segundos
Uso intensivo 5
BR-V
BR-24
230VAC
24VDC
190W
80W
1400
-
1,4A
5A
10µF
-
4,5 SEC
5 SEC
4 MT
4 MT
60%
80%
-20°/+70°
-20°/+70°
35 KG
35 KG
6 3
DANGER: for any maintenance, strike off the supply.
The gear-motor is supplied with permanent grease lubrification and then it doesn't
seg
.
require any maintenance.
For a correct system maintenance, where the gear-motor is inserted, carry on as
follows: clean and free periodically the runner and relative wheels by the debris.
The material removal has to be carried out observing the current laws.

FINAL RECOMMENDATIONS

1_Carry out the grounging.
2_Keep always apart the feeding cables from the bowden control cables.
3_Equip the system with safety devices as:
When the system overlooks a public street, it is necessary to install two of the above
mentioned devices at least (chosen among three models or also of the same type).
4_For the release it is necessary that the gate, when it is closed, doesn't push on the
stop ledges.
5_Carry out the system according to the current regulations.
6_The thrust force check must be given from the presence within the system of a
couple signaller.
7_It is absolutely necessary, the gate is equipped with the stop ledges, before the
gear-motor is installed.
8_According to the current regulations, the gate thrust force doesn't exceed
15daN.
For the setting check, make use of a dynamometer.
9_Any intervention of maintenance, repair and regulation have to be carried out by
qualified personnel.
No starting before the machine, where it will be inbuilt,
has been declared in compliance with the regulations
of the
CEE rules 1998, June 22nd., n° 0037
MAINTENANCE
DISPOSAL
-photocells
-couple limiting devices
-sensible rib
.
6 1 2
6 1 2