DESCRIPTION OF LED INDICATORS AND BUTTONS
1
3
5
1
6V mode. The maximum voltage 7.2V. Suitable for charging 6V batteries < 24Ah.
2
12V mode. The maximum voltage 14.4V. Suitable for charging 12V batteries < 24Ah.
LED indicator of damaged battery. LED indicator lit up - battery is damaged/there is short-
3
circuit/connecting clips are reversed.
LED indicator of charging status. LED indicator is flashing - battery is still charged. LED
4
indicator lit up - battery is fully charged.
5
Button for setting charging modes.
CHARGING
ź
First, make sure the voltage of lead acid batteries you want to charge is 6V/12V and less than 24Ah.
Plug the charger into the electrical outlet (100V - 240V ~50Hz/60Hz).
ź
Connect the red clip to the positive (+) terminal of the battery. Connect the black clip to the negative (-)
ź
terminal of the battery.
If the positive and negative terminals are reversed the LED indicator
ź
The charger has a memory function. After connecting to the outlet it's in the mode that was set the last
ź
time.
ź
Now you can now select the operating mode by pressing the button
After charging, unplug the charger from the electrical outlet.
ź
ź
First remove the clip from the negative terminal and then the clip from the positive terminal.
2
4
will light up.
, see below.
2
OPERATING MODES
6V CHARGING MODE (MAXIMUM CHARGING VOLTAGE 7.2V ± 0.25V, 1A).
Suitable for charging 6V batteries < 24Ah
ź
To select this mode press the button
ź
Charging is automatically set up when the LED indicator
ź
flashes.
Charging is complete when the LED charging indicator
ź
ź
After the battery gets charged the charger will automatically switch to the maintenance charging mode.
12V CHARGING MODE (MAXIMUM CHARGING VOLTAGE 14.4V ± 0.25V, 1A).
Suitable for charging 12V batteries < 24Ah
ź
To select this mode press the button
ź
Charging is automatically set up when the LED indicator
ź
flashes.
ź
Charging is complete when the LED charging indicator
After the battery gets charged the charger will automatically switch to the maintenance charging mode.
ź
AUTOMATIC REGENERATION
This mode is designed to regenerate deeply discharged batteries and cannot be separately set up.
ź
The charger after connecting to the battery, automatically recognizes the battery is deeply discharged
and begin to charge the battery by using lower current. When the battery reaches normal voltage
the charger start charging the battery normally. The maximum time of the regeneration mode
is 20 minutes. If no adequate battery voltage can be achieved during this time, the charger will stop
charging, the battery will be detected as defective and the indicator of damaged battery
up.
DETECTION OF DAMAGED BATTERY
The charger is able to recognize if the battery is damaged, a short circuit occurs, positive and negative
ź
terminals are reversed. In this case the charger will not begin charging but the LED indicator
light up.
CLEANING CHARGER
Disconnect the charger from the battery and from the electrical outlet before cleaning. Use a dry
ź
and soft cloth to clean the outer surface of charger. Do not use any aggressive chemical cleaners.
CHARGER TECHNICAL SPECIFICATION
ź
Operating voltage: 100V - 240V ~50Hz/60Hz.
Output voltage: 7.2V/14.4V (± 0.25V).
ź
Charge current: 1A maximum.
ź
ź
Suitable battery types: lead-acid, gel, AGM batteries with the voltage of 6V/12V.
Recommended battery capacity: 1.2Ah - 24Ah.
ź
ź
Battery maintenance capacity: 1.2Ah - 40Ah.
and wait until the 6V LED indicator
lights up.
lights up and the LED charging indicator
stops flashing and lit.
and wait until the LED indicator
lights up.
lights up and the LED charging indicator
stops flashing and lit.
3
will light
will