Herunterladen Inhalt Inhalt Diese Seite drucken

Manual Programming; Restoring The Default Settings - Motostar LIVI-LS2 Allgemeine Hinweise

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
code 09876 typedonan entry panel's keypad, activates relay-switch 2
for 1 second.

Manual Programming

NOTE. Program the relay-switches only after you have programmed
the system.
You can manually program the device in three ways:
Program individually
This lets you associate each relay-switch to up to 30 separate - even
non-consecutive - users. For example 2, 5, 7, 11, and so on.
1. Set DIP-SWITCHES 5 and 6 so as to choose which relay-switch to
program:
2. Set DIP-SWITCH 3 to OFF and DIP-SWITCH 4 to ON;
3. On each of the indoor receivers, press the button that is to activate the
chosen relay-switch. Each time such button is pressed the ❷ PROG
LED turns on for one second to confirm the programming.
NOTE. To add extra indoor receivers that will also control the chosen
relay-switch. Repeat this procedure only for any extra indoor receivers.
Batch programming
This lets you associate each relay-switch to a batch of - from 2 to 25 -
consecutive users.
1. Set DIP-SWITCHES 5 and 6 so as to choose which relay-switch to
program:
2. Set DIP-SWITCH 3 to ON and DIP-SWITCH 4 to OFF;
3. On the first and last indoor receivers press the button you that want
to use a control button. The❷ PROG LED flashes twice to confirm
the programming.
FG00834M07 - ver. 1 - 09/2017
NOTE. The chosen control needs to be the same on all indoor receiv-
ers. If the chosen control buttons are incongruent with each other,
you will need to reprogram the module after restoring all its factory
settings.
General programming
This mode lets you associate each relay-switch to all the users.
1. Set DIP-SWITCHES 5 and 6 so as to choose which relay-switch to
program:
2. Set DIP-SWITCH 3 and 4 to OFF;
3. On any indoor receiver, press the button that you wish to become the
control button. The ❷ PROG LED flashes twice to confirm the pro-
gramming.
Exiting the programming
- Reset DIP-SWITCHES 5 and 6 to OFF and then reset DIP-SWITCHES 3
and 4 to OFF.

Restoring the default settings

1. Set DIP-SWITCHES 5 and 6 to ON;
2. Set DIP-SWITCHES 3 and 4 to ON;
3. Reset DIP-SWITCHES 5 and 6 to OFF;
4. Reset DIP-SWITCHES 3 and 4 to OFF;
Programming the codes on the DNA
The programming the code on the DNA is explained in the entry panel's
programming manual.