- Installation of the filter assembly below the water level of the pool is highly recommended. In the event that the filter is
installed above the pool water level, a check valve, accessible through a service hatch, must be installed on the
suction line.
- Allow a surface area of 1200 mm x 1200 mm for the installation.
- Position the control panel as close as possible to the multiport valve to facilitate manipulations.
- To prevent vibrations, and any resonance effect, insert a sheet of soft rubber between the base of the pump and the
ground.
F

INSTALLATION RECOMMENDATIONS

INSTALLATION TYPE
A-B : Skimmers
C
: Main drain
D
: Vacuum point
E
: Return fitting
F
: Waste pipe
G
: Valve
G
E
D
13/44
2011/01 - Indice de révision : B - Code : 0026730
C
B
A