Microstream
for Non-Intubated Patients
For use with all Microstream-enabled monitors
Single patient use, not to be re-processed
Non-sterile / non-pyrogenic
Does not contain natural rubber latex
Warning:
Warning:
Warning:
Caution:
Caution:
Caution:
Caution:
Note:
Note:
Note:
Note:
Note:
Note:
Federal law (U.S.) restricts this device to sale by or on the order
of a physician.
2
Loose or damaged connections may compromise
ventilation or cause an inaccurate measurement of
respiratory gases. Securely connect all components
and check connections for leaks according to stan-
dard clinical procedures.
Do not cut or remove any part of the sample line. Cut-
ting the sample line could lead to erroneous readings.
Check CO
and O
2
ensure that no kinks are present. Kinked tubing may
cause inaccurate CO
to patient.
Ensure that tubing is not stretched during use.
Do not attempt to clean, disinfect, sterilize or flush
any part of the sampling line as this can cause dam-
age to the monitor.
Dispose of sampling lines according to standard op-
erating procedures or local regulations for the dis-
posal of contaminated medical waste.
Use of a CO
2
cating that it is for use in humidified environments)
during MRI scanning may cause interference. These
sampling lines include CapnoLine H/Long, Capno-
Line H O
, Smart CapnoLine H/Long, Smart Capno-
2
Line H O
, and Smart CapnoLine H Plus O
2
The use of non H sampling lines is advised.
Replace the sampling line according to hospital pro-
tocol or when a blockage is indicated by the device.
Excessive patient secretions or a build-up of liquids
in the airway tubing may occlude the sampling line,
requiring more frequent replacement.
When connecting a sampling line to the monitor, in-
sert the sampling line connecter clockwise into the
monitor CO
port and turn the connector until it can
2
no longer be turned, to ensure that it is connected se-
curely to the monitor. This will assure that there is no
leak of gases during measurement at the connection
point and that measurement accuracy is not compro-
mised.
Following connection of the CO
that CO
values appear on the monitor display.
2
Expect delay times for the following products to be
longer than the standard by the given times: Long
(4m) FilterLines/CapnoLines - 3 seconds; Nasal
FilterLine Infant/Neonatal - 1 second.
Sampling lines with H in their names include a mois-
ture reduction component (Nafion
for use in higher humidity environments where long
duration use of CO
Sampling lines are recommended for use with oxy-
gen provided at up to 5l/min. At higher levels of oxy-
gen provision, dilution of CO
leading to lower CO
en
EtCO
®
tubing regularly during use to
2
sampling or affect O
2
sampling line with H in its name (indi-
sampling is required.
2
values.
2
Sampling
2
sampling line, check
2
* or its equivalent)
®
readings may occur,
2
delivery
2
/Long.
2