Tunstall 77 0840 00 Installationsanleitung Seite 6

Ran-schnittstelle

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN - Applications
Application: An external call device raises the call type "call".
Application: An external call device raises the call type "cardiac alarm".
DIP switch
(for settings
see below)
0V
0V
RAN
Room bus
+24V-Si
(RAN)
DIP switch 1–3:
DIP switch 4:
Bed number:
Button contact type:
No bed
(i.e. room call)
Bed 1
Bed 2
Bed 3
Bed 4
Bed 5
Bed 6
0V
A B
LED
**
Button
)
Normally open (NO)
DIP switch 5–8:
Button function:
Normally closed
(NC)
Normally open
(NO)
*
)
LED:
Location light: I
Reassurance light: I
**
) Button:
Min. switching current: 0.1 mA, 5 V DC
Max. cable lenght at points 4, 5, 6 = 5 m
*
)
External call device
**
Button
)
Normally closed (NC)
Call type "call"
The call is cancelled in the
nurse call system.
Call type "call"
The call is cancelled automatically, as
soon as the call device is reset.
Call type "cardiac alarm"
The cardiac alarm is cancelled
in the nurse call system.
Call type "cardiac alarm"
The cardiac alarm is cancelled automati‐
cally, as soon as the call device is reset.
6
= 0.5 mA
max.
= 10 mA
max.
The location light is
on with a weak light.
When a call is
raised, it is on with
a bright light as a
reassurance light.
00 8801 97, 01/2017 (Rev. 6.0)