Herunterladen Inhalt Inhalt Diese Seite drucken

Panasonic FY-250ZDY2 Installationshandbuch Seite 8

Vorschau ausblenden Andere Handbücher für FY-250ZDY2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
220~240V
50/60Hz
Power Source
Divide the power lines running to
the switch and the main unit.
On the product, do not attach
more than one cable to each
terminal.
(NEUTRAL)
Operation Switch
(1) 0 (OFF)
(2) 1 (ON)
Air Flow Switch
(3) High
(4) Low
Function Select Switch
(5) Energy Recovery
Switch
Ventilation
(To be procured
(6) Normal Ventilation
locally)
To find out the function of
each switch, refer to Page 8
of the Owner's manual.
■ Use three-core polyvinyl chloride insulated and sheathed cables for fixed wiring that have a cross-
sectional conductive area of 2.5 mm
wire, attach a ring termninal securely at two points as shown right.
(Carry out the work based on the laws, regulations and technical standards of the country concerned.)
■ Follow the following steps for wiring.
• Unfasten two cover-fixing screws of the electrical equipment box, open the box cover, and then connect
wiring firmly.
• Fit the cables from the terminal firmly with a cord clamper.
■ When you need much airflow or a duct is long, change the wire connection from High to Extra High.
• Unfasten two cover-fixing screws of the electrical equipment box and open the box cover.
• Change CN6 to CN5 and CN8 to CN7 inside the electrical Equipment box.
■ It is possible to operate up to 10 units from one switch set.
Caution
• Use the power source corresponding to the name plate. Using a different power source may cause the motor to burn out.
• Carry out grounding work according to the laws and regulations of the country concerned and the technical standard.
• The earth wire must longer than other wires 15-20 mm.
• After completion of wiring, check again there are no wrong wirings before power ON.
Red
Supply Air
Capacitor
Fan
Orange
Yellow
Blue
Yellow
White
Black
Low
High
Common
Low
Extra
High
(LINE)
(Second main body)
Power Source
Third main body
2
and conforms to the IEC 60227-4 standard. When using stranded
Switching Connector
Damper
Motor
Red
Exhaust
Capacitor
Air Fan
Orange
Blue
White
Black
High
Extra
Common
High
Cover-fixing screws of the
electrical equipment box
Electrical Equipment Box
Model No.
FY-800ZDY2
FY-01KZDY2A/B
Model No.
Power Source
220-240V~50Hz/
FY-800ZDY2
220V~60Hz
FY-01KZDY2A
220-240V~50Hz
FY-01KZDY2B
220-240V~60Hz
Model No.
Capacitor
8.0 μF 450VAC
FY-800ZDY2
FY-01KZDY2A
10.0 μF 450VAC
10.0 μF 450VAC
FY-01KZDY2B
Ring terminal
Secure wire
properly
Stranded
Wire
~
15
20mm
Earth
Wire
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis