CAUTIONS for cooling and dehumidification operations:
When using functions on cooling and dehumidification, keep an interval of at least 3 minutes between
-
each power on or off.
Power supply shall meet the requirements.
-
The socket is suitable for AC use.
-
Do not share one socket with other appliances.
-
Power supply is AC220-240V, 50Hz.
-
Water full alarm function of the internal tank
The inner water tank in the air-conditioner has one water level safety switch, it controls the water level. When
water level reaches an anticipated height, the water full indicator lights up. When the water is full, please
remove the rubber stopper from the drainage outlet at the bottom of unit, and drain out all the water.
Continuous Drainage
Under normal use, the unit can evaporate the condensate water automatically by the splash motor. If the water
splash motor is damaged, continuous drainage (drain the water from the bottom outlet) can be used manually.
Under this condition, the water full indicator will light up. Please remove the rubber boot and then the rubber
stopper from the drainage outlet and connect a drain hose to the outlet, then all the water in the water tank
will be drained out. The unit can also work well. But in order not to decrease the efficiency of the performance,
please contact authorized service technician to repair the splash motor as soon as possible.
When you plan to leave this unit unused for a long time, please also remove the rubber stopper from the
drainage outlet at the bottom of unit, and drain out all the water.

CLEANING AND MAINTENANCE

Before cleaning, be sure to disconnect the appliance from any electric supply outlet.
Do not use gasoline or other chemicals to clean the appliance.
Do not wash the appliance directly.
If the appliance is damaged, please contact the dealer or repair shop.
Air Filter
If the air filter becomes clogged with dust/dirt, the air filter should be cleaned once every two weeks.
-
Pull out the air filter from the air inlet grille by the pull tab.
-
Clean the air filter with neutral detergent in lukewarm water (40℃) and dry it up in the shade.
-
Insert the air filter back into the air inlet grille; replace the components as they were.
Clean the Surface
First clean the surface with a neutral detergent and wet cloth, and then wipe it with a dry cloth.
TROUBLESHOOTING
Troubles
Possible Causes
Water full indicator light blinks, and water
Appliance
does
not start when
tank is full.
pressing
the
Room temperature is lower than the
power button
setting temperature.
The doors or windows are not closed.
Not cool enough
There are heat sources inside the room.
Solutions
Remove the rubber stopper to dump
the water out from the drainage outlet.
Reset the temperature.
Make sure all the windows and doors
are closed.
Remove the heat sources if possible.