Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
iCLASS SE® Biometric Reader
3. Mode: Changes the Operational Mode.
4. Select 4 < more > to see the next page of Configuration
options.
Second page of Configuration options
Configuration
1. PIN Required
2. BIO Required
3. Capture Quality
4. < more >
1.
PIN Required
Yes: To require a Local PIN Verify for access.
No: Does not require a PIN for access (Default).
Note: The PIN Required setting can only be changed
from Yes to No if the reader is ordered with the Local
PIN Verify factory configuration option. Also all cards
on site may need to be re-enrolled, because they may
have been previously enrolled when no Local PIN Verify
was required. To facilitate this migration process, It is
suggested that the user sets up one or more separate,
dedicated enrollers that require a Local PIN Verify
and use these enrollers to add PINs to users' cards,
including Admin cards. The site Readers are set to
ignore Local PIN Verify so they will be able to accept
the re-enrolled cards. Once all of the user cards have
been re-enrolled then the rest of the Readers on the
site can be reset to require Local PIN Verify.
2. BIO Required:
Yes: To require a fingerprint presentation for access
(Default).
No: Does not require a fingerprint presentation for
access.
Note: Seos Credentials require a fingerprint template
enrolled on the credential for configuration option
BIO Required = No. A fingerprint will not need to be
presented for this option.
3. Capture Quality:
Low Quality: Only one scan is required when capturing
each fingerprint.
High Quality: Three scans are required when capturing
each fingerprint. This is the recommend mode as the
likelihood of success when a user presents a finger to
gain access is increased.
4. Select 4 < more > to see the next page of Configuration
options.
RKLB40
SRD MODEL: RKCLB40E
Third page of Configuration options
ƒ Firmware: Displays the Firmware information, if
needed, when working with Technical Support.
1. Firmware
2. Visitor Card Enabled
4. < exit >
Note: Press # to bring up a page with the Site Key
number. The Site Key number page is only visible to
Admins and is a hidden option to prevent
unintended display. The Site Key number should be
kept secure. (Option only appropriate when the
Template Type is set to Seos).
ƒ Visitor Card Enabled: This option is only available if
the Template Type is set to iCLASS.
Yes: To allow visitor cards to be used in this
environment.
No: Do not allow visitor cards in this environment
(Default).
If you select Yes and go to Manage Users there will now
be a third choice in the Enrollment dialog: Enroll Visitor.
Visitor cards are prepared ahead of time, are generic, and
can be given to visitors without requiring them to enroll
their biometric information. No fingerprint information will
be processed by the reader. If PIN Required (Local PIN
Verify) is set, visitors will need to be told what the Local
PIN Verify PIN value is to permit access.
Select 4 < exit > to return to the first screen of
Configuration options.

4.3 Sensor Cleaning

For optimum performance, it is recommended that you
clean the bio-reader periodically. The use of a dry cloth is
recommended to clean the acquisition surface. In order
not to scratch the surface, remove all dust and residue with
gentle movements.
CAUTION: Acidic liquids, alcohol or abrasive materials are
prohibited.
4.4 Additional References
Documents kept up-to-date and available on-line:
ƒ iCLASS SE Biomectric Reader Advanced Use Case
Application Note -
ƒ iCLASS SE Biometric / iCLASS SE Display Reader
Installation Guide -
5
Configuration
www.hidglobal.com/PLT-03345
www.hidglobal.com/PLT-02738
PLT-03342, Rev. A.3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis