LED DIAGNOSTICS
The red LED DL1 indicates the activation of inputs according to the legend hereunder:
STOP
on with fixed light
PHOT
rapid flashing
DOWN
1 flash with 2-second interval
UP
2 flashes with 2-second interval
DOWN+UP
3 flashes with 2-second interval
By flashing slowly, the red LED DL1 also indicates that the unit is powered.
The green LED and the output SCA (DIP 4OFF) indicate the direction of the movement of the motor and
the status of the bollard, as follows:
Lowering bollard
1 flash /1 relay switching with 1 sec. delay
Raising bollard
2 flashes/ 2 relay switching with 1 sec. delay
Bollard in lower position (without TCA) ON with fixed light /N.C. contact
Bollard in lower position (with TCA)
2 flashes/ 2 relay swicthing per sec.
Bollard in raised position
LED OFF/ N.O. contact
HY.TERM
Adjustable thermostat for cold places
Connect to the control panel to HY.TERM input as indicated (Fig. 2) . The thermostat is supplied into a
waterproof box for outdoor installation and it is equipped with 1m cable.
If the temperature drops below the set value the control panel makes the motor to keep the oil warm. We
suggest to set the HY.TERM at a temperature of -5°C.
HY.BUZZ
Acustic warning device . Connect the device by means of the power circuit AC/DC supplied , as indicated
in Fig.3
The acustic warning device will indicate the raising of the bollard (DIP 4)
The acustic device cannot be installed outdoor , we suggest to locate it into the control panel plastic box
or into another plastic box with the same IP rate.
HY.VLL / HY.VLV
Electronic circuit for the control of the LED light (HY.LED) or (HY. VA) Electrovalve for automatic lowering
in case of power failure.
Connect the circuit as indicate ( Fig.4)
The Leds indicate the status of the bollard:
During the raising cycle : fast flashing
WASTE DISPOSAL
If the product must be dismantled, it must be disposed according to regulations in force regarding the
differentiated waste disposal and the recycling of components (metals, plastics, electric cables, etc..). For
this operation it is advisable to call your installer or a specialised company.
14
OPTIONALS
SERVICE MAN MODE
With all DIPs on ON, the control unit switches to SERVICE MAN mode.
The DOWN/UP push-buttons must be kept pressed during operation. The opening of the STOP input
stops the motor.
The contemporary pressure of DOWN/UP stops the motor.
PRE-WARNING ACTIVATION/DEACTIVATION (DIP2:ON)
Immediately after putting the DPI1 in ON position the red led light DL1 indicates the activation or the
deactivation of the preflashing
Con il DIP2 è possibile attivare o disattivare la funzione prelampeggio.
The DIP 2 allows to activate or deactivate the preflashing function.
DIP2 ON: preflashing activated , the lights start flashing 5 sec. before the raising cycle starts
DIP2 OFF: preflashing deactivated.
RADIO SELF-LEARNING
The HY.CELL control unit is equipped with a built-in radio module for the fixed or roll-on code of remote
controls, with 433.92MHz frequency.
To use a remote control, it is first necessary to store its code in memory. The memorisation procedure is
described hereunder. The device is able to store up to 64 different codes in memory.
By pressing P1, the control unit enters the radio learning phase: DL1 red LED flashes 1 time per second,
awaiting the key to the matched to the DOWN function;
When the key is stored in memory, exit from the programming mode;
Pushing twice P1 the red led light DL1 flashes twice per second waiting for the assignment of the push
button to be assigned to UP function.
When the key to be matched is memorised, exit from the programming mode.
Pushing three times P1 , the red LED light DL1 flashes 3 times per second waiting for the assignment of
the push button to be assigned to STEP BY STEP function.
Once assigned the push button to the relevant functions the programming is completed.
In case you don't need to memorize any transmitter, keep the button P1 pressed until the red light DL1
start flashing again in the way that indicates the presence of network (see diagnostics LED pag.7)
To reset the memory of the receiver, press and keep P1 and P2 keys pressed for around 10 seconds
(during this period of time, both DL1 and DL2 flash rapidly).
After 10 seconds, when the two LEDs are switched on with fixed light, release the push-buttons.
When the LEDs switch back again to the original configuration, the control unit has completed the memory
reset.
NOTE:
The transmitters are memorised on an EPROM memory (U2), which can be extracted from the control unit
and inserted in a new HY.CELL control unit should a replacement is required.
For safety reasons, the transmitters can be stored in memory during the raising/lowering of the motor.
TRANSMITTER REMOTE LEARNING
If the transmitter code is already stored in the receiver, the remote radio learning can be carried out
(without accessing the control unit).
IMPORTANT: The procedure should be carried out with gate in the lowering phase, during the TCA
dwell time.
Proceed as follows:
1 Press the hidden key of the transmitter, the code of which has already been stored in memory.
2 Within 5 seconds, press the already memorised transmitter key corresponding to the channel to be
matched to the new transmitter. The flashing light switches on.
3 Within 10 seconds, press the hidden key of the new transmitter.
4 Within 5 seconds, press the key of the new transmitter to be matched to the channel selected at item 2.
The flashing light switches off.
5 The receiver stores the new transmitter code and exits from the programming mode immediately.
13