Herunterladen Inhalt Inhalt Diese Seite drucken

Electric Diagram - Enar SPYDER PRO Serie Gebrauchsanweisungen

Frequenzumformer und rüttenllanzen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Make sure that the current is off during repairs.
PROBLEM
Not working,
green led (1) OFF
Led (2+3) ON ó
Yellow led (3) ON
Yellow led (3) ON
+ Green led (1)
ON
Blue led (4) ON +
Green led (1) ON
The poker is
noisier
en
The vibrating
poker works
correctly
but it overheats
10
SPYDER PRO - GUN
2V 38, 2V 50, 2V 60, 2V 70, 1V 38, 1V 50, 1V 60
See if it has power
Check cord
Check plug
Converter burnt out
Stator poker burnt out
Converter burnt out
Earth leakage current (check poker, connections)
Water inside converter or poker
Lack of phase in poker (3 phase motor). Check connections and cables
Bearings are not in good conditions.
Check the poker is not working out of concrete.
Verify the input voltage of the converter.
Bearings in bad conditions or without lubrication

ELECTRIC DIAGRAM

CAUSE
FRECUENCY CONVERTER AND POKERS