Herunterladen Inhalt Inhalt Diese Seite drucken

Operation And Maintenance; Getting Started; Converter Connection To The System; Disconnecting The Equipment - Enar SPYDER PRO Serie Gebrauchsanweisungen

Frequenzumformer und rüttenllanzen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The motor plug should not be used to start or stop the equipment.
The electrical feeding cable should not be used to remove the plug from the socket.
AVOID the flattening of the cable by heavy machinery which could cause breakage.
Be sure that the parts of the poker are tight before starting work.
Keep the converter clean and dry.
Make sure that the electrical cable extension is with the proper section and functioning properly.
Before doing any work of maintenance, disconnect the motor from the electrical system.
When connecting to a generator, make sure that the out tension and frequency is stable , right and has the
proper power.
(the converter feeding voltage should not vary than +/- 5% as stated on the converter plate.
The level of acoustic pressure is less than 80 dB (see table point 2). Proper protective equipment
should be used.
The vibration that transmits to the operator does not exceed 2,5m/s
2.
The vibrating pokers should not be working out of concrete more than 5 minutes.
Be sure that the parts of the poker are tight before starting work (welding points).
When finishing the job or when taking a break, the operator should switch off, disconnect it from the electrical
system, place it in such a way that should not fall or tip.
IN ADDITION, LOCAL COUNTRY STABLISHED ORDINANCES SHOULD BE RESPECTED.

OPERATION AND MAINTENANCE

4.

4.1 GETTING STARTED

Read item 3 USAGE CONDITIONS

4.2 CONVERTER CONNECTION TO THE SYSTEM

The model SPYDER PRO 2V is connected to the main 230V +-5% / 50-60Hz (single phase) and the model
SPYDER PRO1V is connected to the main 115V / 50-60Hz (single phase).
Use a residual current device ("rcd") with a rated tripping current of 30mA for each converter. Rcd should be
installed either at the distribution board which feeds the mains supply sockets or at the fixed main supply
socket. Do not plug others electric tools to the rcd where is plugged the converter.
Gun version
Switch on the converter. Push one time the push button to start the poker, push again to stop the poker.
From pressing to switch off, wait 5 seconds before pressing again to start the poker.

4.3 DISCONNECTING THE EQUIPMENT.

Stop the converter by disconnecting the proper switch, and finally remove the plug from the main.

4.4 EARTH CONNECTION

To protect the user from an electrical shock, the converter should be correctly connected to earth.
The converters are equipped with three cables and their respective plugs. The adequate earth socket should
be used to connect the converters. If the socket with earth is not available, an earth adapter should be used
before connecting the plugs.

4.5 EXTENSION CABLES

Always use extension cables with earth wire and its respective plug with earth in the female and male plug.
Do not use damaged or worn out cables.
Avoid heavy loads on cables.
To determine the transversal section, follow the following procedure:
FRECUENCY CONVERTER AND POKERS
2
of acceleration. See table in point
2V 38, 2V 50, 2V 60, 2V 70, 1V 38, 1V 50, 1V 60
SPYDER PRO - GUN
en
7

Werbung

Inhaltsverzeichnis
loading