Massedurchfluss von gasen und flüssigkeiten. steuer- und auswerteelektronik (78 Seiten)
Inhaltszusammenfassung für Brooks 585xEMH series
Seite 1
Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 ® Brooks Model 585xEMH High Temperature Mass Flow Controllers Model 5850EMH High Temperature Model 5851EMH High Temperature Thermal Mass Flow Controller Thermal Mass Flow Controller...
Seite 2
Read before proceeding! Brooks Instrument designs, manufactures and tests its products to meet many national and international standards. These products must be properly installed, operated and maintained to ensure they continue to operate within their normal specifications. The following instructions must be adhered to and integrated into your safety program when installing, operating and maintaining Brooks Instrument products.
Seite 3
We appreciate this opportunity to service your flow measurement and control requirements with a Brooks Instrument device. Every day, flow customers all over the world turn to Brooks Instrument for solutions to their gas and liquid low-flow applications. Brooks provides an array of flow measurement and control products for various industries from biopharmaceuticals, oil and gas, fuel cell research and chemicals, to medical devices, analytical instrumentation, semiconductor manufacturing, and more.
Seite 4
Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Contents Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Paragraph Page Number Number Section 1 Introduction How to Use This Manual ......................1-1 Description ..........................1-1 Specifications ..........................1-1 Section 2 Installation General ............................2-1 Receipt of Equipment .........................
Seite 6
Contents Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Figures Figure Page Number Number Dimensions - Model 585xEMH with D-Connector and VCR Fittings .......... 1-3 MFC Mounting Hole Positions for Models 5850EMH & 5851EMH ..........2-3 Connecting and Tightening Process Connections ..............
Back Cover Warranty, Local Sales/Service Contact Information 1-2 Description The Brooks Models 5850EMH and 5851EMH Mass Flow Controllers are used in gas flow handling systems that require high ambient/operating temperatures such as vapor flow control. Unlike standard mass flow controllers, the 585xEMH has two distinct modules connected by a signal cable.
Seite 8
Section 1 Introduction Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 Table 1-1 585xEMH Specifications P P P P P erformance erformance erformance erformance erformance 5850EMH 5850EMH 5850EMH 5850EMH 5850EMH 5851EMH 5851EMH 5851EMH 5851EMH...
Seite 9
Section 1 Introduction Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 5850EMH 5851EMH Figure 1-1 Dimensions - Model 585xEMH with D-Connector and VCR Fittings...
Seite 10
Section 1 Introduction Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
If the packing case is damaged, the local carrier should be notified at once regarding his liability. A report should be submitted to your nearest Product Service Department. Brooks Instrument 407 W. Vine Street P.O. Box 903...
Model 585xEMH February, 2016 2-4 Return Shipment Prior to returning any device to the factory, visit the Brooks web site (www.BrooksInstrument.com) for a Return Materials Authorization Number (RMA#), or contact one of the locations provided on p. 2-1. Prior to returning the device, it must be purged in accordance with the...
Seite 13
Section 2 Installation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 Recommended installation procedures: a. The Model 585xEMH should be located in a clean, dry atmosphere relatively free from shock and vibration. b. Leave sufficient room for access to the 15-pin Dsub connector located at the top portion of the cover pointing towards the control valve.
Seite 14
Section 2 Installation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 g. Once the controller is correctly mounted, connect the inlet and outlet ® fittings to the gas supply line. 1. Install new gaskets compatible with the gas to be used.
Section 2 Installation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 Figure 2-3 Remote Electronics Box Mounting Diagram The remote electronics box can be mounted in any position that is convenient, within reach of the high temperature cable. The temperature limit of the electronics is 0-50°C (32°F-122°F).
Section 2 Installation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 Figure 2-4 Common Electrical Hookups 2-9 Operation Procedure a. Mount the controller & remote electronics box in their final location and orientation. b. Apply any and all heater devices and thermal insulation around the controller and the process lines.
Section 3 Operation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 3-1 Overview After the flowmeter has been properly installed in the process line, it is ready for operation. When initiating flow, slowly open the valve to avoid a flow surge.
Seite 18
Section 3 Operation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 Figure 3-2 Externally Accessible Adjustments at Remote Electronics Box Figure 3-3 External 15-Pin D-Sub Connector at Remote Electronics 15 Pin D-Connector 15 Pin D-Connector...
Section 3 Operation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 3-3 Theory of Operation The thermal mass flow sensing technique used in the Model 585xEMH operates as follows: A precision power supply provides a constant power heat input (P) at the heater which is located at the midpoint of the sensor tube.
Seite 20
Section 3 Operation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 Figure 3-6 Flow Control System Block Diagram Figure 3-7 Customer Connections and Settings...
Section 3 Operation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 The flow restrictor shown in Figure 3-5 performs a ranging function similar to a shunt resistor in an electrical ammeter. The restrictor provides a pressure drop that is linear with flow rate.
Section 3 Operation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 3-5 Adjustment Potentiometers All Model 585xEMH instruments are factory calibrated for optimum performance. The only potentiometer recommended for field adjustment is the Zero. Reference Figure 3-2 to access the Zero Potentiometer adjustment screw.
Turn on the process gas supply. Each device is factory adjusted to provide a zero ±10 mVdc at zero flow. The adjustment is made in Brooks’ calibration laboratory which is temperature controlled to the temperature specified at the time of order.
Seite 24
Section 3 Operation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 Figure 3-8 Bench Troubleshooting Circuit Calibration Procedure for the Standard Response PC Board a. With the controller installed in an unpressurized gas line, apply power and allow approximately 45 minutes for warm-up.
Seite 25
Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 Note: The voltage at TP1 is -100 times the output voltage of the sensor. This voltage can range from -1.2 to -12 Volts, however, it is recommended that this voltage stay between -2.0 and -9.0 Volts for proper operation.
Section 3 Operation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 Note: The voltage at TP2 can range from -10 to +3 Volts. It is recommended, however, that this voltage stay between -2.5 and +2.5 Volts for proper operation.
Seite 27
Section 3 Operation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 a. Set the command to zero percent flow rate (0.000 V) and allow the flow signal output to stabilize (30 seconds minimum). Step change the command to 100% of flow (5.000 V) and record the output signal from the...
Seite 28
Section 3 Operation Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 THIS PAGE WAS INTENTIONALLY LEFT BLANK 3-12...
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 4-1 Overview...
Seite 30
The breakout board( P/N S273Z668AAA) D-Connector version available from Brooks Instrument, will make this job much easier. 2. Verify that the process gas connections have been correctly terminated and leak-checked.
Seite 31
Note: Do not attempt to disassemble the sensor. D. Cleaning Procedures No routine external cleaning is required for Brooks thermal mass flow controller. Should the 585xEMH Mass Flow Controller require cleaning due to deposition, return the device to Brooks Instrument for servicing by...
Seite 32
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Table 4-1 Bench Troubleshooting Trouble Possible Cause Check/Corrective Action Actual flow overshoots setpoint by Anticipate potentiometer out of adjustment. Adjust anticipate potentiometer. Refer to Sections 3-5 & 3-8 .
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Table 4-2 Sensor Troubleshooting SENSOR SCHEMATIC FUNCTION Heater Upstream Temperature Sensor (Su) Downstream Temperature Sensor (Sd) Sensor Common Heater Common Remove the sensor connector from the PC Board for this procedure.
Seite 34
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 In order to calculate the conversion factor for a gas mixture, the following formula should be used: Where, = percentage (%) of gas 1 (by volume)
Seite 35
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Table 4-3 Conversion Factors (Nitrogen Base) DENSITY SENSOR ORIFICE GAS NAME FORMULA SEMI ID FACTOR FACTOR (km/m 1 1 2-Trichloro-1 1 2-Triflouroet f-113 C2Cl3F3 0.231...
Seite 36
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Table 4-3 Conversion Factors (Nitrogen Base) (Continued) DENSITY SENSOR ORIFICE GAS NAME FORMULA SEMI ID FACTOR FACTOR (km/m Bromine Pentafluoride BrF5 0.287...
Seite 37
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Table 4-3 Conversion Factors (Nitrogen Base) (Continued) DENSITY SENSOR ORIFICE GAS NAME FORMULA SEMI ID FACTOR FACTOR (km/m Diethylsilane C4H12Si 0.183 1.775...
Seite 38
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Table 4-3 Conversion Factors (Nitrogen Base) (Continued) DENSITY SENSOR ORIFICE GAS NAME FORMULA SEMI ID FACTOR FACTOR (km/m Hydrogen Iodide 0.953 2.144...
Seite 39
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Table 4-3 Conversion Factors (Nitrogen Base) (Continued) DENSITY SENSOR ORIFICE GAS NAME FORMULA SEMI ID FACTOR FACTOR (km/m Oxygen 0.988 1.067 1.429...
Seite 40
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Table 4-3 Conversion Factors (Nitrogen Base) (Continued) DENSITY SENSOR ORIFICE GAS NAME FORMULA SEMI ID FACTOR FACTOR (km/m Trichlorofluoromethane f-11 CCl3F 0.374...
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 4-4 Orifice Sizing The Orifice Sizing Nomograph, Figure 4-1, is used to calculate the control valve's orifice size when changing any or all of the following factors from...
Seite 42
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Figure 4-1 Model 585xEMH Orifice Sizing Nomograph 4-14...
Seite 43
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Example: 2,000 sccm 2,000 x .269 538 sccm Nitrogen In order to calculate the orifice conversion factor when using a gas mixture,...
Seite 44
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 3. Determine Critical Pressure Drop Critical pressure drop occurs when the outlet pressure (psia) is less than half the inlet pressure (psia) or...
Section 4 Maintenance & Installation and Operation Manual X-TMF-585xEMH-MFC-eng Troubleshooting Part Number: 541B212AAG Brooks ® Model 585xEMH February, 2016 Figure 4-2 Example Nomograph 4-5 Restrictor Sizing The restrictor assembly is a ranging device for the sensor portion of the controller. It creates a pressure drop which is linear with flow rate. This diverts a sample quantity of the process gas flow through the sensor.
Seite 46
The Model 585xEMH mass flow controller/device uses the Anti-Clog Laminar Flow Element (A.C.L.F.E.). Sizing All Model 585xEMH Series Restrictor Assemblies are factory adjusted to provide a specific pressure drop for each flow rate. This corresponds to the desired full scale flow rate. Contacts Brooks Instrument for recommended restrictor size and part number.
P ed instalací si p e t te následující instrukce! Spole nost Brooks Instrument konstruuje, vyrábí a testuje tento produkt tak, aby splnil mnoho národních a mezinárodních standard . P ístroje musí být ádn nainstalovány, používány a udržovány tak, aby byl zajišt n jejich nep etržitý provoz v rámci normálních technických specifikací. Musíte dodržovat následující...
Seite 49
Om kvalitet af signalkabler, kabeltilslutninger og koblinger: Brooks tilbyder kabler af højest kvalitet, som er tilpasset CEE kvalificeringens forskrifter. Hvis man vælger at bruge egne kabler, skal man vælge et kabel som har den nødvendige afskærmning for at sikre 100 % mod udefra kommende støj.
Seite 50
Lees ze voordat u verder gaat! Brooks Instrument ontwerpt, produceert en test haar producten zodanig dat ze voldoen aan vele nationale en internationale normen. Deze producten moeten correct worden geïnstalleerd, bediend en onderhouden zodat ze binnen hun normale specificaties blijven werken.
Olulised juhised Enne kasutamist lugege hoolikalt läbi! Brooks Instrument konstrueerib, valmistab ja katsetab oma tooteid selliselt, et need vastaksid paljudele riiklikele ja rahvusvahelistele standarditele. Ainult nõuetekohane paigaldamine, kasutamine ja hooldamine tagab toodete katkematu talitluse tavaspetsifikatsiooni raames. Brooks Instrumenti toodete paigaldamisel, kasutamisel ja hooldamisel tuleb täita alljärgnevaid juhiseid ja integreerida need asjakohasesse ohutusprogrammi.
Seite 52
PED direktiiviä koskevat määräykset löytyvät käyttöoppaan ’’Tekniset tiedot” -luvusta. Käyttöoppaassa kuvatut tuotteet ovat 97/23/EC EU-direktiivin mukaisia. Kaikki Brooks Instrumentin virtausmittarit kuuluvat ryhmään 1. Laitteet, jotka ovat suurempia, kuin 25 mm tai 1 tuuma, ovat PED I, II, III kategorien mukaisia.
Seite 53
AVERTISSEMENT: n’utilisez pas cet instrument au-delà des spécifications énumérées dans le manuel d’utilisation. Le non-respect de cet avertissement peut entraîner de graves blessures et / ou endommager l’équipement. • Si vous ne comprenez pas l’une des instructions, prenez contact avec un représentant de Brooks Instrument pour obtenir des explications. •...
Seite 54
Produkte mit einer Größe von 25 mm oder 1“ (inch) oder kleiner sind Sound Engineering Practice (SEP). Europäische Verordnung zur elektromagnetischen Verträglichkeit (EMV) Geräte von Brooks Instrument (elektrischer und elektronischer Art) mit CE-Zeichen haben den Test auf Einhaltung der Verordnung zur elektromagnetischen Verträglichkeit (EMV Richtlinie 2004/108/EC) erfolgreich bestanden.
Seite 55
Section A Essential Instructions Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG February, 2016 ® Brooks Model 585xEMH Greek Brooks Instrument Brooks Instrument. ’ Brooks Instrument. : (1) . (2) Brooks Instrument. (PED) 0,5 bar (g) 25 mm (PED). PED.
Seite 56
üzemeltetni és karbantartani ahhoz, hogy mindenképpen a normál m ködési tartományuknak megfelel en üzemelhessenek. Az alábbi utasításokat be kell tartani, és be kell építeni a munkavédelmi programba a Brooks Instrument termékeinek telepítése, üzemeltetése és karbantartása során.
Seite 57
Direttiva europea relativa alla compatibilità elettromagnetica (EMC) Le apparecchiature (elettriche/elettroniche) Brooks Instrument dispongono del marchio CE ed hanno superato positivamente i test per i requisiti di compatibilità elettromagnetica (Direttiva EMC 2004/108/EC). In ogni caso bisogna prestare particolare attenzione alla scelta dei cavi di segnale utilizzati per le apparecchiature con marchio CE.
Seite 58
Lai nodrošin tu šo izstr d jumu turpm ku darb bu atbilstoši noteiktajiem parametriem, tie ir pareizi j uzst da, j lieto un j apkopj. Uzst dot, lietojot „Brooks Instrument” izstr d jumus un veicot to apkopi, ir j iev ro šie nor d jumi un j iek auj tie j su droš bas programm .
Seite 59
SP JIMAS: nenaudokite šio prietaiso viršydami instrukcijoje ir eksploatacijos vadove nurodytus techninius duomenis. Nesilaikydami šio sp jimo galite sunkiai susižeisti ir (arba) sugadinti rang . Jei nesuprantate koki nors nurodym , kreipkit s „Brooks Instrument“ atstov , kad paaiškint . Paisykite vis sp jim , persp jim ir nurodym , pažym t ant gaminio arba pateikt su juo.
Seite 60
Produkty o wielko ci 25 mm lub 1 cala lub mniejsze podlegaj zaleceniom „Uznanej Praktyki In ynierskiej” (SEP). Europejska dyrektywa dotycz ca kompatybilno ci elektromagnetycznej (EMC) Urz dzenia elektryczne / elektroniczne firmy Brooks Instrument posiadaj ce oznaczenie CE, przesz y pozytywnie testy pod k tem spe niania przez nich wymogów kompatybilno ci elektromagnetycznej (Dyrektywa EMC 2004/108/EC).
Seite 61
Ler antes de proceder! A Brooks Instrument projecta, fabrica e testa os seus produtos de forma a satisfazer numerosas normas nacionais e internacionais. Estes equipamentos devem ser instalados, utilizados e mantidos de forma adequada, e devem funcionar dentro da sua gama de utilização. As instruções seguintes devem ser, durante a instalação, uso e/ou manutenção dos equipamentos da Brooks Instrument, apreendidas e integradas no plano de...
Seite 62
În m sura în care indica iile c r ii ma inii nu sunt suficient de l muritoare, lua i leg tura cu reprezentantul Brooks Instrument pentru clarificarea problemei.
Seite 63
Pre íta pred inštaláciou! Brooks Instrument svoje výrobky projektuje, vyrába a testuje takým spôsobom, aby tieto vyhoveli domácim aj medzinárodným normám. Tieto zariadenia je potrebné predpísaným spôsobom inštalova , prevádzkova a udržiava , na zabezpe enie ich spo ahlivej a normálnej prevádzky v celom pracovnom rozsahu.
Seite 64
Pred servisom morate odstraniti tlak v obdelovalni liniji. e potrebujete rezervne dele, zagotovite, da usposobljeno osebje uporablja rezervne dele, ki jih je odobrila družba Brooks Instrument. Neodobreni deli in postopki lahko vplivajo na u inkovitost delovanja izdelka ali ogrozijo varno upravljanje postopka.
Seite 65
¡Léalos primero! El Brooks Instrument proyecta, fabrica y prueba sus productos de manera que éstos respondan a numerosas normas nacionales e internacionales. Dichas instalaciones deben ser emplazadas, operadas y mantenidas adecuadamente, para que puedan marchar de todas formas en conformidad con el alcance normal de funcionamiento.
Seite 66
Läs detta innan du fortsätter! Brooks Instrument konstruerar, tillverkar och testar sina produkter med syfte att uppfylla alla nationella och internationella standarder. Dessa produkter måste installeras på rätt sätt, handhas och underhållas för att de skall fungera kontinuerligt enligt deras normala specifikation. De följande anvisningarna bör följas och integreras till Ert säkerhetsprogram varje gång när Brooks Instruments produkter installeras, handhas och underhålls.
Seite 67
Installation and Operation Manual X-TMF-585xEMH-MFC-eng Part Number: 541B212AAG ® Brooks Model 585xEMH February, 2016 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
Seite 68
BROOKS SERVICE AND SUPPORT Brooks is committed to assuring all of our customers receive the ideal flow solution for their application, along with outstanding service and support to back it up. We operate first class repair facilities located around the world to provide rapid response and support.