1 - Communicating Generator equipped with Opentherm protocol
Carry out the "boiler" A connection, disconnecting the relay card (output with voltage-free contact) code SK16504.
FZ4B
L _ N
L _ N L _ N
L _ N
L
L
L L
X01
X02
X03
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
3 - Stand alone 2: Generator without Opentherm protocol (ON/OFF) with temperature control
Carry out the "boiler" B connection, connecting the relay card (output with voltage-free contact) code SK16504.
Carry out the "sensor" C connection.
FZ4B
L _ N
L _ N L _ N
L _ N
L
L
L L
X01
X02
X03
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
One direct zone
RY1
RY2
7 (L)
8 (N)
9 (L)
10 (N)
318a
318a
318a
318a
72a Room thermostat 1st zone (direct) / 138 External probe / 139a Remote Timer Control 1st zone (direct) / 318a Circulating pump 1st zone (direct)
Two direct zones
RY1
RY2
7 (L)
8 (N)
9 (L)
10 (N)
318a
318a
318b
318a
318a
318b
72a Room thermostat 1st zone (direct) / 72b Room thermostat 2nd zone (direct) / 138 External probe / 139a Remote Timer Control 1st zone (direct) / 139b Remote Timer Control 2nd zone (direct) / 318a Circulating pump 1st zone (direct) / 318b Circulating pump 2nd zone (direct)
Three direct zones
RY1
RY2
7 (L)
8 (N)
9 (L)
10 (N)
318a
318a
318b
318a
318a
318b
72a Room thermostat 1st zone (direct) / 72b Room thermostat 2nd zone (direct) / 72c Room thermostat 3rd zone (direct) / 138 External probe / 139a Remote Timer Control 1st zone (direct) / 139b Remote Timer Control 2nd zone (direct) / 139c Remote Timer Control 3rd zone (direct)
One mixed zone
RY1
RY2
7 (L)
8 (N)
9 (L)
10 (N)
318a
318a
315a - A
315a - B
318a
318a
315a - A
315a - B
72a Room thermostat 1st zone (mixed) / 138 External probe / 139a Remote Timer Control 1st zone (mixed) / 315a Mixing valve 1st zone (mixed) - A = OPENING PHASE, B = NEUTRAL, C = CLOSING PHASE
317a Safety thermostat 1st zone (mixed) / 318a Circulating pump 1st zone (mixed) / 319a Delivery sensor 1st zone (mixed)
Two mixed zone
RY1
RY2
7 (L)
8 (N)
9 (L)
10 (N)
318a
318a/318b
315a - A
315a - B
318a
318a/318b
315a - A
315a - B
72a Room thermostat 1st zone (mixed) / 72b Room thermostat 2nd zone (mixed) / 138 External probe / 139a Remote Timer Control 1st zone (mixed) / 139b Remote Timer Control 2nd zone (mixed) / 315a Mixing valve 1st zone (mixed) - A = OPENING PHASE, B = NEUTRAL, C = CLOSING PHASE /
315b Mixing valve 2nd zone (mixed) - A = OPENING PHASE, B = NEUTRAL, C = CLOSING PHASE / 317a Safety thermostat 1st zone (mixed) / 317b Safety thermostat 2nd zone (mixed) / 318a Circulating pump 1st zone (mixed) / 318b Circulating pump 2nd zone (mixed) /
319a Delivery sensor 1st zone (mixed) / 319b Delivery sensor 2nd zone (mixed)
One mixed zone and one direct zone
RY1
RY2
7 (L)
8 (N)
9 (L)
10 (N)
318a
318a
315a - A
315a - B
318a
318a
315a - A
315a - B
72a Room thermostat 1st zone (mixed) / 72b Room thermostat 2nd zone (direct) / 138 External probe / 139a Remote Timer Control 1st zone (mixed) / 139b Remote Timer Control 2nd zone (direct) / 315a Mixing valve 1st zone (mixed) - A = OPENING PHASE, B = NEUTRAL, C = CLOSING PHASE /
317a Safety thermostat 1st zone (mixed) / 318a Circulating pump 1st zone (mixed) / 318b Circulating pump 2nd zone (direct) / 319a Delivery sensor 1st zone (mixed)
One mixed zone and two direct zones
RY1
RY2
7 (L)
8 (N)
9 (L)
10 (N)
318a
318a
315a - A
315a - B
318a
318a
315a - A
315a - B
72a Room thermostat 1st zone (mixed) / 72b Room thermostat 2nd zone (direct) / 72c Room thermostat 3rd zone (direct) / 138 External probe / 139a Remote Timer Control 1st zone (mixed) / 139b Remote Timer Control 2nd zone (direct) / 139c Remote Timer Control 3rd zone (direct) /
315a Mixing valve 1st zone (mixed) - A = OPENING PHASE B = NEUTRAL C = CLOSING PHASE / 317a Safety thermostat 1st zone (mixed) / 318a Circulating pump 1st zone (mixed) / 318b Circulating pump 2nd zone (direct) / 318c Circulating pump 3rd zone (direct) / 319a Delivery sensor 1st zone (mixed)
Two mixed zones and one direct zone
RY1
RY2
7 (L)
8 (N)
9 (L)
10 (N)
318a
318a/318b
315a - A
315a - B
318a
318a/318b
315a - A
315a - B
72a Room thermostat 1st zone (mixed) / 72b Room thermostat 2nd zone (mixed) / 72c Room thermostat 3rd zone (direct) / 138 External probe / 139a Remote Timer Control 1st zone (mixed) / 139b Remote Timer Control 2nd zone (mixed) / 139c Remote Timer Control 3rd zone (direct) /
315a Mixing valve 1st zone (mixed) - A = OPENING PHASE, B = NEUTRAL, C = CLOSING PHASE / 315b Mixing valve 2nd zone (mixed) - A = OPENING PHASE, B = NEUTRAL, C = CLOSING PHASE / 317a Safety thermostat 1st zone (mixed) /
317b Safety thermostat 2nd zone (mixed) / 318a Circulating pump 1st zone (mixed) / 318b Circulating pump 2nd zone (mixed) / 318c Circulating pump 3rd zone (direct) / 319a Delivery sensor 1st zone (mixed) / 319b Delivery sensor 2nd zone (mixed)
One hot water tank circuit
RY1
RY2
7 (L)
8 (N)
9 (L)
10 (N)
318a Hot water tank circulating pump / 155 Hot water tank probe
10
X15
BUS RT1 RT2 RT3
T1
T2
T3 T4
BLR
X09
X10
X11
X12
X13
X14
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
A
X15
SCHEDA RELÉ
BUS RT1 RT2 RT3
T1
T2
T3 T4
BLR
X09
X10
X11
X12
X13
X14
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
C
RY3
RY4
RY5
11 (L)
12 (L)
13 (L)
14 (N)
RY3
RY4
RY5
11 (L)
12 (L)
13 (L)
14 (N)
318b
318b
RY3
RY4
RY5
11 (L)
12 (L)
13 (L)
14 (N)
318b
318c
318c
318b
318c
318c
RY3
RY4
RY5
11 (L)
12 (L)
13 (L)
14 (N)
315a - C
315a - C
RY3
RY4
RY5
11 (L)
12 (L)
13 (L)
14 (N)
315a - C
318b
315b - A
315b - B
315a - C
318b
315b - A
315b - B
RY3
RY4
RY5
11 (L)
12 (L)
13 (L)
14 (N)
315a - C
318b
318b
315a - C
318b
318b
RY3
RY4
RY5
11 (L)
12 (L)
13 (L)
14 (N)
315a - C
318b
318c
318b/318c
315a - C
318b
318c
318b/318c
RY3
RY4
RY5
11 (L)
12 (L)
13 (L)
14 (N)
315a - C
318b
315b - A
315b - B/318c
315a - C
318b
315b - A
315b - B/318c
RY3
RY4
RY5
11 (L)
12 (L)
13 (L)
14 (N)
318a
2 - Stand alone 1: Generator without Opentherm protocol (ON/OFF)
Carry out the"boiler" B connection, connecting the relay card (output with voltage-free contact) code SK16504
L _ N
L _ N L _ N
L
L
X01
X02
X03
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
B
SK16504
A - Connect to boiler Opentherm Remote Timer Control (139)
B - Connect to boiler On/Off room thermostat (72)
C - Generator delivery sensor
RY6
RY7
RT1
RT2
15 (L)
16 (L)
19 - 20
21 - 22
72a/139a
72a/139a
RY6
RY7
RT1
RT2
15 (L)
16 (L)
19 - 20
21 - 22
72a/139a
72b/139b
72a/139a
72b/139b
RY6
RY7
RT1
RT2
15 (L)
16 (L)
19 - 20
21 - 22
72a/139a
72b/139b
72a/139a
72b/139b
RY6
RY7
RT1
RT2
15 (L)
16 (L)
19 - 20
21 - 22
72a/139a
72a/139a
RY6
RY7
RT1
RT2
15 (L)
16 (L)
19 - 20
21 - 22
315b - C
72a/139a
72b/139b
315b - C
72a/139a
72b/139b
RY6
RY7
RT1
RT2
15 (L)
16 (L)
19 - 20
21 - 22
72a/139a
72b/139b
72a/139a
72b/139b
RY6
RY7
RT1
RT2
15 (L)
16 (L)
19 - 20
21 - 22
72a/139a
72b/139b
72a/139a
72b/139b
RY6
RY7
RT1
RT2
15 (L)
16 (L)
19 - 20
21 - 22
315b - C
318c
72a/139a
72b/139b
315b - C
318c
72a/139a
72b/139b
RY6
RY7
RT1
RT2
15 (L)
16 (L)
19 - 20
21 - 22
318a
FZ4B
L _ N
L L
BUS RT1 RT2 RT3
T1
T2
X09
X10
X11
X12
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
RT3
T1
T2
23 - 24
25 - 26
27 - 28
RT3
T1
T2
23 - 24
25 - 26
27 - 28
RT3
T1
T2
23 - 24
25 - 26
27 - 28
72c/139c
72c/139c
RT3
T1
T2
23 - 24
25 - 26
27 - 28
319a
319a
RT3
T1
T2
23 - 24
25 - 26
27 - 28
319a
319b
319a
319b
RT3
T1
T2
23 - 24
25 - 26
27 - 28
319a
319a
RT3
T1
T2
23 - 24
25 - 26
27 - 28
72c/139c
319a
72c/139c
319a
RT3
T1
T2
23 - 24
25 - 26
27 - 28
72c/139c
319a
319b
72c/139c
319a
319b
RT3
T1
T2
23 - 24
25 - 26
27 - 28
155
B
X15
SCHEDA RELÉ
SK16504
T3 T4
BLR
X13
X14
T3
T4
29 - 30
30 - 31
138
T3
T4
29 - 30
30 - 31
138
T3
T4
29 - 30
30 - 31
138
T3
T4
29 - 30
30 - 31
138
T3
T4
29 - 30
30 - 31
138
T3
T4
29 - 30
30 - 31
138
T3
T4
29 - 30
30 - 31
138
T3
T4
29 - 30
30 - 31
138
T3
T4
29 - 30
30 - 31
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis