5. Fuse replacement

If a short circuit occurs due to fan overload, the fuse will
blow. Even if the Clima Control Eco does not operate at
all, in the worst case, this could indicate a blown fuse.
The fuse (8A or 15A, depending on the version of your
Clima Control Eco) must then be replaced.
To replace the fuse, go through the following steps (the
fuse holder is placed on the left front side of the
controller to the left of the rotary knob "BOX MIN"):
1. Press the black fuse holder slightly with a
screwdriver and turn it a quarter of a turn
counterclockwise.
2. Remove the fuse holder.
3. Remove the fuse.
4. Insert a new 8 or 15 amp fuse (depending on the
version of your Clima Control Eco).
5. Reinstall the fuse holder in the housing of the Clima
Control Eco.
6. Then press the fuse holder again with a screwdriver
and tighten it by turning it a quarter turn clockwise.
Your Clima Control Eco is ready for use again.