Setup
Pay attention to the technical data. The permissible voltage of max. 10 V/DC and the
permissible current of max. 2.4 A must not be exceeded.
The USB power meter adapter is used as an accessory for one or two multimeters. The adapter
can be connected to a digital or analogue multimeter (not included) with suitable connectors.
• Perform the current and voltage measurement simultaneously or separately. Connect the
cables according to the connection options shown below.
• Connect the test leads (7) to the connectors (2, 3, 4, 5) of the USB power meter adapter and
to one or two multimeters (DMM or analogue). Make sure that the colour codings on the test
leads and on the adapter (black and red) match.
• Connect the USB-A plug (1) to the power supply (e.g. 5 V/DC power bank or USB power
supply).
• Connect a USB cable (not included) to the USB-A port (4) and the other end of the cable to
your consumer (e.g. smartphone).
a) Voltage measurement
DMM
DMM
v
C
A
V
Test leads
USB power meter adapter
5 V/DC
b) Current measurement
DMM
DMM
mA
c
A
V
Test leads
USB power meter adapter
c) Current and voltage measurement
DMM
2x DMM
v
c
A
V
Test leads
Device
Power supply (e.g. USB power supply)
Device
5 V/DC
Power supply (e.g. USB power supply)
DMM
Device
mA
c
A
V
USB power meter adapter
5 V/DC
Power supply (e.g. USB power supply)

Care and Cleaning

• Disconnect the product from the power supply and the connected devices before cleaning
the product.
• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may
damage the case or cause the product to malfunction.
• Use a dry, lint-free cloth to clean the product.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product according to
the relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to environmental protection.

Technical Data

Operating voltage ......................... 5 V/DC (max. 10 V/DC)
Operating current .......................... max. 2.4 A
Test leads ..................................... 4 pairs each with 4 mm plug (1x black, 3x red)
Cable length of the test leads ....... 118 cm each (including plug)
USB cable length .......................... 18 cm
Operating/storage conditions ........ -10 to +50 °C, <90% RH
Dimensions (L x W x H) ................ 114 x 35 x 26 mm (without USB cable)
Weight .......................................... 52 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or capturing in
electronic data processing systems) requires prior written approval from the publisher. Reprinting, also in part, is
prohibited. This publication reflects the technical status at the time of printing.
Copyright 2019 by Conrad Electronic SE.
*1716077_V1_0319_02_hk_m_en

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis