Herunterladen Inhalt Inhalt Diese Seite drucken

Equipotential Connection - Ideal Standard MOMENTS Installations- Betriebs Und Wartungshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
E
QUIPOTENTIAL CONNECTION
The tub must be connected to the equipotential system of the buil-
ding by a cable with a section of 2.5÷6mm
by means of the terminal marked with
support (fi g.2).
O
PERATION CHECK
After carrying out electrical and hydraulic connections and prior to
fastening the tub in place, perform an operation check by following
the instructions below:
- Move the tub far enough away from the wall to be able to see
all hydraulic fi xtures.
- Close the contact of the omnipolar switch for the electrical system
by placing the lever in position I.
- Check that the LED of the push button O/I comes on steady red.
- Check the colours of the various LED according to the table be-
low.
- Switch the system on and back off as a test at least twice.
Phase
Stand-by
Light operation
20
TT0288264_00_Moments.indd 20
T
ROUBLESHOOTING
Problems
2
. Connection is performed
The button (O/I)
, located on the metal
LED does not
come on
B
ULB REPLACEMENT
Remove side panel "A" and front luminous panel "B". Remove screws
"C" as shown in fi gure and replace the neon inside (type L 58W/840
ø26mm l.1500mm).
(Fig.2)
Led
Lit red
Lit green
Probable cause
Recommended action
the system is not
check that the ominpolar
powered
switch is in position "I "(on)
Disconnect from the power supply before replacing the
neon lights.
C
A
B