Mounting
Before mounting this product, read the
Mounting Diagram
Bracket
ÉPIX Flex 20
Cutting to Length
Each ÉPIX Flex 20 can be cut to length to accommodate custom installations. Any ÉPIX Flex 20 that is cut to length must
be used as the last product linked to an output port of the ÉPIX Flex Drive.
DISCONNECT the product from power before cutting to length.
DO NOT cut across electrical components.
Any ÉPIX Flex 20 that is cut to length must be used as the last product linked to an output port of
the ÉPIX Flex Drive.
Termination Kit
After cutting an ÉPIX Flex 20 to length, seal the included end cap to the exposed end of the product with the included
silicone glue:
1. Disconnect the product from power.
2. Apply the silicone glue to the exposed end of the product.
3. Insert the exposed end of the product into the end cap.
4. Wipe away any excess glue.
5. Allow to dry before reconnecting to power.
The end cap must be sealed completely to maintain the IP67 rating of the product.
Handling Warnings
Never twist the ÉPIX Flex 20.
Never coil the ÉPIX Flex 20 sideways. If necessary, it is recommended to store the product on a reel or drum.
Always retain the ÉPIX Flex 20 on the included spool when it is not installed. The ÉPIX Flex 20 should never
be folded, placed un-spooled in a box or any other carrying case or stored in any manner other than around
the included spool.
ÉPIX Flex 20 QRG Rev. 4
QUICK REFERENCE GUIDE
Safety
Notes. Use 1 of the included brackets every 1.6 ft (0.5 m).
DO NOT Cut Here
Insert Screws Here
Cut