EN-8
Type (TYPE)
Allows the selection of normally open or normally closed relay
functions. Selections are Open, Closed*.
O p e n
O p e n
O p e n
= The initial state of the Relay output is normally open.
O p e n
O p e n
Closed = The initial state of the Relays output is normally closed.
*NOTE: The normally closed condition is only active while the Indicator is
powered on. When powered off, the relays return to a normally open condition.
Sequence (SEQ)
Allows alteration of the relay operating sequence as the weight
reading changes from under / accept / over.
Selections are: Normal, hold.
Normal = The previously enabled relay will be disabled as
the next relay is enabled.
Hold
= The previously enabled relay will hold the same
state as the next higher relay is enabled.
Contact (CONTAC)
Allows alteration of relay contact closure.
Selections are: Sim, BBM, MBB.
Sim
= Simultaneous. Relays open or close at the same time.
BBM
= Break-Before-Make contact style.
MBB
= Make-Before-Break contact style.
END (-END-)
Represents the end of the menu.