Herunterladen Inhalt Inhalt Diese Seite drucken

General Guidelines - HQ Power VDP150CG Kurzanleitung

Spectral wizz 150
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

3. General Guidelines

• This device is designed for professional use on stage, in discos, theatres, etc. The VDP150CG should only be
used indoors with an alternating current of max. 230V AC/50Hz.
• Lighting effects are not designed for permanent operation: regular operation breaks will prolong their lives.
• Do not shake the device. Avoid brute force when installing or operating it.
• Select a location where the device is protected against extreme heat dust and moisture. Respect a minimum
distance of 0.5m between the device's light output and the illuminated surface.
• Use an appropriate safety cable to fix the device (e.g. VDLSC7 or VDLSC8).
• Familiarise yourself with the functions of the device before actually using it. Do not allow operation by unqualified
people. Damage is most often caused by unprofessional use of the device.
• Use the original packaging if the device is to be transported.
• All modifications of the device are forbidden for safety reasons.
• Only use the device for its intended purpose. All other uses may lead to short circuits, burns, electroshocks, lamp
explosion, crash, etc. Using the device in an unauthorised way will void the warranty.
4. Installation
a) Lamps
• Only fit or replace a lamp when the device is unplugged from the mains.
• Let a lamp cool down before replacing it as the temperature of a lamp can reach 700°C during operation. Wait at
least 10 minutes before opening the housing.
• Do not touch a halogen lamp with your bare hands. Use a cloth to insert or remove it.
• Do not install lamps with a higher wattage as they generate higher temperatures than those for which the device
was designed.
• Replace any deformed or damaged lamp with a lamp of the same type.
• Install an EFR GZ6.35 lamp (15V/150W) (ordercode : LAMP150/15)
Procedure
1) Unscrew the 4 screws on the bottom of the housing.
2) Gently remove the lower half of the housing.
3) Remove the old lamp and insert the new one.
4) Reposition the lower half of the housing and fasten the screws.
Remark: Do not operate the device with an open housing.
b) Fuse
• Only fit or replace a fuse when the device is unplugged from the mains.
• If the lamp burns out, chances are you will need to replace the fuse as well.
• Replace a blown fuse with a fuse of the same type and ratings (see "7. Technical Specifications" on p. 4):
1. Unscrew the fuse holder at the back with an appropriate screwdriver.
2. Remove the old fuse and install a new one.
3. Replace the fuse holder.
VDP150CG
2
VELLEMAN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis