Herunterladen Inhalt Inhalt Diese Seite drucken

Chauvet 4BAR Flex Schnellanleitung Seite 4

Vorschau ausblenden Andere Handbücher für 4BAR Flex:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
4BAR™ Flex QRG
AC Power
Power Linking
Fuse
Replacement
(Power Linking)
Fuse
Replacement
(Power In)
Mounting
Product
Mounting
Diagram
This product has an auto-ranging power supply that can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
You can link up to 12 4BAR™ Flex units at 120 VAC and 21 units at 230
VAC.
To replace the power linking fuse in the 4BAR™ Flex:
1. Disconnect the product from power.
2. Using a flat-head screwdriver, loosen the fuse holder and pull
straight out.
3. Remove the blown fuse from the holder and replace with a fuse of the
exact same type and rating.
4. Re-insert the fuse holder and reconnect power.
To replace the power-in fuse in the 4BAR™ Flex:
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the safety cap out of the housing.
4. Remove the blown fuse from the clip on the front of the safety cap and
replace with a fuse of the exact same type and rating.
5. Re-insert the fuse holder and reconnect power.
Before mounting this product, read the Safety Notes.
Tilt adjustment
Pod pan adjustment
Tripod insertion
4
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis