5.2.2
Configuration mode
The configuration mode must be activated, in order to program the sensor with
the remote control.
Activation: - Automatically after the sensor is connected to
the supply voltage or
- Briefly disconnect the sensor from the supply voltage or
- Press either key [<] or [>] on the sensor or
- Enter the access code via the remote control (chap. 5.2.5)
+
Exiting:
- Press key
A
- Automatically after 30 min.
5.2.3
Establishing the connection
The connection between the remote control and the sensor can only be esta-
blished after activating the configuration mode (see chap. 5.2.2).
Without addressing:
1. Press the start key
G
- G and one of the keys 1 to 4 light up: Connection successfully established
- G flashes: Connection not established
→ Activate configuration mode
→ Hold remote control closer to the sensor and point directly at it
→ Check batteries in remote control
- No keys light up
→ Check/replace batteries in remote control
Note:
If no entry is made for 30 s, the connection is ended. The settings
made up to that point are saved.
5.2.5
Function access code
The sensor can be protected against unwanted manipulation by third parties with a four-digit access code. The configuration mode can be activated with this code at
any time on the remote control in order to change the sensor settings. The "access code" function can be reached by entering the key code
pressing the key
.
C
The "access code" function is deactivated as standard, i.e., a code is not stored.
Activating the access code (store code)
The code can only be stored if the sensor is already in configuration mode. The device is protected as soon as the code is stored for the first time, i.e. the configuration
mode is deactivated.
G
Establish the connection
(chap. 5.2.3)
099582, 70705-9-9506 Ä-St. 7
combination or
3
With addressing:
1. Cover the IR interface
of the remote control with
your hand
2. Press the start key
G
3. Release the IR interface
(remove hand)
4. Press the corresponding numerical
key (
to
)
1
4
+
C
9
Press
+
C
9
+
light up, i.e. the "access
C
2
code" function is deactivated
(no code is stored)
Montageanleitung Merkur S
5.2.4
Sensor addressing
Each sensor can be assigned an address (1*, 2, 3 or 4). Different addresses are
necessary when several sensors are within the range of a remote control.
flashes
G
Code
Enter a 4-digit code (freely selectable
from 1111 to 9998)
Address 1*
Address 2
Address 3
Address 4
+
and is completed by
C
9
C
4x
Confirm by pressing
C
+
light up, i.e. the "access
C
1
code" function is activated
(the code has been stored)