ACCESSORIES
Accessories
-Electro stimulator
-Carry case
-2 connection cables
-Case of 4 reusable adhesive electrodes (5 x 5 cm)
-Case of 4 reusable adhesive electrodes (5 x 9 cm)
-3 battery stylos 1,5 V AAA
-Operating manual
This stimulator is supplied complete of cables and electrodes. When you open the packing verify that the simulator equip-
ment is complete. If some of the above mentioned accessories are missing, you should immediately contact the shopkee-
per. Also check the stimulator and electrodes integrity.
Electrodes: The electrodes are usable by only one user they are self-adhesive and do not need gel. The electrode cable is
female. They are branded CE complied with MDD 93/42/EEC requirements.
All the information can be subject to changes without notice.
The symbols mean that the apparatus is in accordance with medical CE requirements type BF.
It is forbidden the reproduction and the copy of this manual without written permission of producer. REV. ING. 3.0
2
20/02/2004
14.34
Pagina
4

Accessories on request

-Ball pen
-Kit splitter (2 connectors + 2 connection cables) (4 channels
with 8 electrodes)
-Conductive band for legs
-Face electrodes
-Y cables
-Gel

PRECAUTIONARY MEASURES

This symbols warns you to read the operating instructions prior to use
Contraindications
-Do not stimulate the neck region (carotid sinus).
-Patients who have a demand type cardiac pacemaker.
-Stimulation should be not used on cancer patients (previous permission received by the oncologist).
-Do not stimulate the cerebral zone.
-Do not use on undiagnosed pains until aetiology is established.
-Do not use on sores and dermatological diseases.
-Do not use on acute traumas.
-Do not stimulate recent cicatrix.
-Do not use during pregnancy.
-Do not use driving car.
-It is absolutely forbidden to stimulate the ocular and genital zone
-It is also forbidden the use of the stimulator in the water ( it is not protected against the water seepage). Not to use the
stimulator in environment where combustible gas, inflammables, or oxygen are present.
-It is also required to use with caution in case of capillary fragility because an excessive stimulation could
cause the break of more quantity of capillaries. Anyway it is always preferable to contact your doctor befo
re using.
Adverse possible effects
Skin irritation can occur in rare case. In case of allergic reactions by the use of gel, stop the treatment and contact the
specialist doctor.
If during the stimulation treatment tachycardia or extrasistolia should appear, it is better to stop the treatment the sen-
sation will pass immediately.
Precautions for using
-Do not make any modifications or repairs by yourself. Authorized centres can only execute the repairs.
-Do not give a shock to the product by clashing, overturning or shaking. It may cause a trouble or accident in a long
run although no immediate trouble occurs.
-Store the electro stimulator at a place free from a splash or water. Avoid installing at places subject to undue humi-
dity, temperature, dust or places exposed to direct sunbeam.
-Do not use thinner, gasoline, kerosene, cleaning powder or chemicals; for cleaning the machine it is sufficient a
soft duster
-Take away the battery from the electro stimulator in case of prolonged no use.
-After a long period of no use it is advisable to check the correct working.
-For cleaning the machine and the cables, it is sufficient a soft duster lightly humid.