Herunterladen Inhalt Inhalt Diese Seite drucken

Ambient Conditions; Operation; Performing A Measurement; Hygiene Treatment - Seca b41 Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

2 .4 Ambient conditions

Ideal storage/use temperatures are between 0 °C and +40 °C with a relative
humidity of below 85%.

3 . OPERATION

3.1 Selecting cuff size
First select a suitably-sized cuff for the circumference of the extremity. The table
below provides information about the relevant sphere of application.
Size 1
Infant
10.0 – 15.0 cm circumference
Size 2
Young child
14.0 – 21.5 cm circumference
Size 3
Adult/small
20.5 – 28.0 cm circumference
Size 4
Adult
27.0 – 35.0 cm circumference
Size 5
Adult/large
34.0 – 43.0 cm circumference
Size 6
Thigh
42.0 – 54.0 cm circumference

3 .2 Performing a measurement

The cuff is applied so that the lower edge of the cuff is approx. 2 to 3 cm above
the elbow/approx. 5 cm above the knee joint. Note the marking for artery position
as you do this. Wind the cuff around the extremity neither too loosely nor too
tightly, and ensure that the edge of the marking is within the permitted range. Close
the valve on the air drain screw. The pressure required (approx. 30 mmHg above
expected systolic pressure) is generated in the cuff by pumping the inflation bulb just
a few times. The valve is opened slowly and blow-off speed metered to 2 to 3 mmHg
per second. Using a stethoscope, it is now possible to auscultate Korotkoff sounds.
Once measurement is complete, open the valve to vent the cuff completely.
NOTE
• Modification for left and right-handed use, seca b10, b11 and b12
1 .
2 .
8 •
Free from PVC, DEHP and latex
Free from PVC, DEHP and latex
Free from PVC, DEHP and latex
Free from PVC, DEHP and latex
Free from PVC, DEHP and latex
Free from PVC, DEHP and latex
• MR suitability of the seca b11 and b12
The seca b11 and b12 pressure gages were tested for suitability for use in a
magnetic resonance (MR) environment in combination with the cuffs and their
Velcro closures. Both the requirements on functionality and on electromagnetic
attractive force were met with a range using 3 Tesla. This is indicated by the
marking "MR Conditional" on the scale.

4 . HYGIENE TREATMENT

4 .1 Cleaning and caring for the pressure gage
NOTICE! Damage to device
Unsuitable cleaning agents and disinfectants may damage the sensitive
surfaces of the device.
• Do not use aggressive or abrasive cleaning agents.
• Do not use white spirit or petroleum spirit.
• Only use disinfectants suitable for sensitive surfaces. Suitable disinfectants
are available from specialist dealers.
• For cleaning, we recommend a damp cotton or microfiber cloth wetted
with disinfectant if appropriate.
• Prevent liquids from penetrating the housing.
4.2 Cleaning and caring for the cuffs
Care information for seca blood pressure cuffs with Velcro closure and D-ring:
NOTICE! Damage to device
Never autoclave the cuffs.
Washing
Once the bladder has been removed, at up to 30 °C + detergent for delicates.
Fold covers with Velcro closures before washing so that the two halves of the
Velcro tape are in contact.
Cleaning by
We recommend the following cleaning products and disinfectants:
spraying or
• mild soap
wiping with
• Bacillol AF
disinfectant
• Meliseptol
• Oxivir Plus spray
• Terralin Protect
• 70%-strength isopropyl alcohol
• Fugaten
spray (Lysoform spray)
®
Following cleaning/disinfecting, wipe over with clean water to remove all residues
and then leave to air-dry. Please use only soft cotton or microfiber cloths.
English
• 9

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

B40B11B12B31B30B10

Inhaltsverzeichnis