WIREMAP TEST SCREEN
If more detail is required about the Wiremap Test, the Wiremap screen can be displayed by
highlighting the Wiremap Test icon on the HOME screen and pressing Enter.
Summary
Shows the status or result of the test. In this example, pins 1 and 2 are reversed, resulting in a
miswire fault. Ethernet is tolerant of such a fault, so the Data Test will pass in this case. That is why
it is important to perform both the data test and the wiremap test to prove that the cable meets all
of the required quality standards.
Cable Type
Shows cable type selected in
Remote Unit pin numbers
Shows the overall cable length
Press F1 (RUN) to run the
Wiremap test for
troubleshooting (result can not
A split pair is a wiring error in which each pin is connected to the correct pin at the other end of the cable, but
the pairs of pins are connected using wires from different twisted pairs. Split pairs can cause crosstalk and
data failures, but are not reported as faults by simple wiremappers. The advanced wiremapper in SignalTEK
CT can detect split pairs that some other wiremappers can not detect. Split pairs can start with a simple wiring
error. In the example below, pins 3 and 4 are reversed at one end of the cable:
5
4
3
6
If the error is repaired at end of the cable where the fault is located, the fault is removed:
5
4
3
6
If the error is repaired at the wrong end of the cable, the end-to-end continuity is corrected,
but a split pair is formed:
5
4
3
6
This cable may cause Ethernet data errors, and if so it will fail the SignalTEK CT Data Test.
156840.02
SETUP
be saved)
Test Status:
Ready to test
Test in progress
Test Passed
Test Failed
Shows the length of each pair (some
pairs may be longer than the overall
cable due to the cable construction)
Test Unit pin numbers
Press F3 (SETUP) to adjust the
test settings
Press F2 (FAULT) to view the fault details
5
4
3
6
5
4
3
6
5
4
3
6