EN
Connecting the fixture to 12 V
The already installed lamp means the fixture is immediately ready for
use. Therefore you do not need to install the lamp first. Caution! Do not
open the spotlight yourself. The warranty is no longer valid if the seal
is broken.
Step 1
The MINI SPOT can be attached to the wall using the accompanying
wall mount, or be placed in the ground using the ground pin.
Wall-based assembly:
a. Fix the wall mount in place using the accompanying screw (and
possibly plug). (Fig. 4)
b. Create a round hole of at least 14mm in the surface so the cable
can be passed through it.
c. Assemble the MINI SCOPE light source to the wall mount using the
screw. (Fig. 5)
d. Press the soft rubber wall plug around the cable and, together with
the cable, push it inside the hole for the cable duct. The wall plug
can be used to give the cable duct a water-proof seal. (Fig. 6)
Ground-based assembly:
a. Screw the wall mount to the ground pin using the accompanying
torx screw.
b. Assemble the MINI SCOPE light source to the wall mount using the
screw.
c. Insert the MINI SCOPE into the ground.
Step 2
Join the Easy-Lock connector to the main cable. (Fig. 2)
a. There are two cable ducts. The duct with the narrowest slot is suit-
able for the 14/2 and 10/2 main cable. When using the old (thick)
10/2 cable, you should use the duct with the wide slot.
b. Clamp the correct cable duct on top of the main cable. There
should be no space left between the cable and the duct.
c. Place the cable duct (with the cable at the bottom) in the Easy-
Lock connector.
d. Tighten the threaded cap on the Easy-Lock connector. This will
cause the contacts to be pushed through the insulation on the
cable. In tightening the cap, a little gel is applied to the contacts in
the Easy-Lock connector. This serves to protect the contacts
against moisture. A little gel may possibly come out of the Easy-
Lock connector: so after installation (and/or before a meal), wash
your hands with soap and water, and avoid the gel coming into
contact with your eyes.
Step 3
Connect the main cable to the fixture by connecting the mini-
connector. (Fig. 3) If the lamp does not work correctly, check that the
Easy-Lock connector is properly connected to the main cable. Do the
same for the mini-connector. Repeat steps 2 and 3. When the fixture is
connected to the main cable also check that the contacts of the Easy-
Lock connector are not bent. If you have any problems, contact your
dealer.
General maintenance advice
We advise wiping the fixture down at least once a year using a clean
cloth and warm water.