2-way switching:
NEUTRAL
LIVE / PHASE
Setting the Address and "All Lights On/All Lights Off/All Units Off" Option:
To change the address and set up the "All Lights On/All Lights Off/All Units
Off " option the unit must first be put into Program Mode. To enter Program
Mode either send "Address On" and "Address Off" in a quick sequence or
press the external key quickly . After the relay changes state 5 times, with
no more than 1.75 seconds between each change of state, the unit will
enter Program Mode and the relay will stop responding to indicate that it
has entered the Program Mode.
Once in Program Mode the new address can be set by sending an
"Address" or "Address On" or "Address Off" message on the new address
code twice (using any X10 controller). If you want to change the code
again, just send the revised code twice – as before .
To set the unit to respond to "All Lights On" and/or "All Lights Off" and/or "All
Units Off" just send these messages twice on the new address code (using
any X10 controller).