X10 HOME AUTOMATION
SWITCH OFF APPROPRIATE MAINS FUSE BEFORE INSTALLING!
(INSTALLERS ONLY)
This module can be activated by using a toggle switch or a push button or
using X10 PLC signals. It can be operated using the following X10 signals:
"Address On", "Address Off" and "All Lights On/All Lights Off/All Units Off" if
this option is programmed.
The unit will accept either a momentary acting key or a standard wall
switch with latching action. All key closures must be to Live. If a
momentary key is used, the relay changes state each time the key is
pressed, as long as the key press lasts for less than 1.75 seconds. If a
standard wall switch with latching action is used, it is assumed that the key
press will last for more than 1.75 seconds. In this case the relay changes
state on both the closure and opening. This type of response will allow the
unit to also perform 2-way control if 2 changeover latching switches are
connected in series – as would be the case with 2 way switching.
Installation
To install the AW12, neutral and phase are required at the installation
point.
Switch off appropriate mains fuse and master switch!
-Take the wall switch out of the wall box.
-Disconnect all wires from the switch
-Pull an additional Neutral wire if it is missing
-Connect the live and neutral to the terminal wires of the AW12 as
described in the drawing.
-Connect the wires from the In-Wall module to the switch.
-Connect the phase to the switch
-Re-install the wall switch on the wall box
-Switch on mains fuse and master switch
Programming
Default Setting:
The default factory address is A1. If the address and "All lights on/All lights
off /All Units Off" option settings are not known, the default address of A1
can be set by applying power to the unit and sending the address P16 to
the unit twice (using any X10 controller - i.e.: TM13 + RF remote control).
This can either be just the address "P16" or "P16 On" or "P16 Off". The
messages must be sent within 30 seconds of applying power to the unit.
Setting the default address automatically cancels the options to respond
to either "All Lights On", "All Lights Off" or "All Units Off".
AW12
2