  • DEUTSCH, seite 14
TYPE
Name
Location
Volume (l)
Voltage (V)
Heating performance (W)
Current input (A)
Heating time
From 15ºC to 65ºC (h)
Standby energy use at
65ºC
(Wh/24h)
Water connection
Weight empty (kg)
Rated water pressure (MPa)
Largest opening pressure of
safety valve (MPa)
In-built safety controlling
elements
Other protection
Applicable touch protection: Touch protection class I. It can be connected to electric system supplied with protective earthing as defined in IEC 60364 .
The most important instructions regarding the product are the following: EN 60335-1, EN 60335-2-21. Storage and transportation requirements
regarding the product is EN 60721-3.

8. TECHNICAL DATA

AQ30ErP
AQ50ErP
Hot water tank with closed internal circulation system
30
50
1,0
1,8
0,77
0,89
16,2
19,7
AQ80ErP
AQ100ErP
Vertical wall
80
100
230~
1800
10
2,8
3,5
1
1,3
G1/2
27,4
29,4
0,6
0,7
Built-in temperature control device /
combined control safety-valve
Active anode based corrosion protection
13
AQ120ErP
AQ150ErP
120
150
4,2
5,3
1,5
1,7
32,4
38,5
AQ200ErP
200
2400
16
5,3
2,53
52

Werbung