Domestic hot water sensor
The domestic hot water (DHW) sensor is used to measure the temperature of the domestic hot water in the tank.
It is connected to the control panel.
TAS simulation connector
The connector deactivates the TAS protection, and must only be used if the tank is equipped with a magnesium
anode.
1. Assembly
Refer to the heating generator manual.
2. Connection
Refer to the control panel manual.
Do not place probe wires (very low voltage) and 230 V supply wires in the same duct or cable
raceway. Ensure a minimum distance of 10 cm between very low voltage cables and 230 V power supply
cables.
With SCB-10 :
If there is only one tank, connect the sensor with its connector for tDHW and fit the TAS simulator for TA.
To create a second tank, convert either zone A or B to domestic hot water.
To do this, replace the connector fitted on the sensor cable with the grey connector supplied in the bag and
fit the sensor for TflowA or TflowB.
B
N L
N
6
X15
TS
+
B
TS
A
N L
N
+
A
1
N L
Tsyst
X14
2
C
B
Tflow
Tsyst
Tdhw
Tflow
ou
15/11/18 - 300000550-05
EN
A
+TA-
Tflow
MW-IMG2-30000550