Table 2: Error codes
Error code(s)
Description
1, 2 , 3
Internal battery charger
problem.
4
Temperature too low.
5
Temperature too high
7
Current too high.
If the cause of the failure has been removed, the battery charger can be restarted by
disconnecting and reconnecting the mains .

6. Specifications

specifications / model
Supported batteries
Battery capacity range
Mains voltage
Mains frequency
Output voltage range
Output current range
Maximum output power *
Efficiency
Protections
Dimensions
Charge status indication
Use
Operational temperature range *
Storage temperature
Cooling
Maximum humidity
Safety class
Regulations
Standards
* At elevated ambient temperatures or if there is no sufficient cooling, the output current
can be reduced.
Possible causes and solution(s)
Restart battery charger. If the error is repeated
Consult Your supplier.
Move to a warmer environment and restart the
charging.
Let the charger cool down for 15 minutes and
restart the charging. If the problem persists
please consult Your supplier.
Cabling problem or other problem. Check cabling
and connections and restart. If unsuccessful
consult Your supplier.
6A
Lithium iron phosphate (LiFePO4) 25.6V of 2 x 12.8V
12-60Ah
16-80Ah
220-240Vac
nominal,
50/60 Hz
25.6V nominal, 29.2V maximum charge voltage
0.25 – 6A
0.25 – 8A
180W
240W
> 90% at full load and 230Vac
Output voltage , Temperature
210 x 175 x 65mm
2 LEDs
Indoor use only
0 – 40°C
-15 - +50°C
Passive
Passive
95% (non condensing)
CE (LVD, EMC, RoHS)
EN60335-2-29 , EN12184 , ISO7176-14, EN60601-1-2
19
English
8A
24-120Ah
(single phase)
0.25 – 12A
360W
Active (Fan)
II
12A

Werbung