10.1
Operating voltages and main switch
The eStore Battery Management System (BMS) assesses the state of each
cell in the battery, deciding when to protect the battery by opening the main
switch.
The Main Switch works as follows:
eStore state
Discharging
Charging
10.2
Charging eStore
A
NOTICE!
eStore can be charged with Dometic eCore or Waeco
PerfectCharge MCA series chargers (choose power mode; see
charger manual for appropriate DIP switch setting). Use of third
party chargers is permitted. The main switch will remain closed
when charging under normal conditions if the following charger
parameters are met:
 end of charge voltage: between 13.8 V and 14.0 V
 maximum output 40 A (30 A recommend) per installed eStore
For further information please contact Dometic (see addresses on
the back page).
I
NOTE
Please also refer to the manual of the charger.
EN
Main Switch behavior
< 30 A, 11 – 12 V: main switch opens
> 30 A, 10 – 11.8 V: main switch opens
These are indicative values and are given as guidance only.
The main switch opening voltage depends on internal
parameters such as cell voltage and temperature, and
discharge current. The indicated current values are valid per
single eStore.
The main switch opening voltage depends on internal
parameters such as cell voltage and temperature, and charge
current. The maximum voltage above which the main switch
opens is 15.2 V. Charging with the recommended charging
parameters will ensure the main switch remains closed during
normal operation.
See chapter "Charging eStore" on page 23 for recommended
charging parameters.