CLEANING AND CARE

Warning: Make sure the heater is in off position and is cool!
Warning: Do not clean heater with cleaners that are combustible or corrosive.

TROUBLESHOOTING

4
44
must not be stored in garage or any other enclosed area. Only store in venti-
lated area!
Storage of heater indoors is permissible only if the cylinder is disconnected
and removed from the heater.
Check the tightness of the gas valve and for damage. If you suspect a dama-
ge, have it changed by your gas dealer.
Never store liquid gas cylinder in a sub-terrain, or at places without adequate
air ventilation.
Wipe off powder coated surfaces with soft, moist rag and soap water.
Remove debris, spider and insect nests from ventilation opening of the cylin-
der enclosure, control compartment, burner and circulation air passageways
of the heater with heavy duty pipe cleaner or compressed air to keep appli-
ance clean and safe for use.
Never clear ports or other openings with toothpicks or other article that will
break and block the ports.
Problem
Cause
No electricity supply
The motor does not
work
The safety thermostat
is on
The cylinder gas tap is
closed
The cylinder is empty
The motor works, but
The nozzle is obstruct-
the burner does not
light up and after few
ed
seconds the heater
The solenoid gas valve
stops
is not open
There is no spark
No connection with
the earthing system
The burner lights up
Defective connection
but after few seconds
between sensor and
the heater stops
safety device
Defective safety device Replace the safety device
Excessive gas supply
Insufficient air flow
The heater stops
during operation
Insufficient gas supply
due to ice formation
on the cylinder
Solutions
Check the terminal board
with a tester
Wait about one minute then
restart
Open the gas tap
Use a new cylinder
Remove the nozzle and
clean it.
Check that the solenoid
valve works
Check the position of elec-
trode
Check and connect properly
Check and connect properly
Check the pressure reducer
and if required replace it
Check that the motor works
properly
Check and use a larger
cylinder or two cylinders
connected together.