3 Fit the supplied pipe clips
in fixed positions, press the unit into the pipe clips and
(O)
tighten the 3-way connection
. Pay hereby attention to the correct position of the
(I)
sealing rings
, both with regard to the connections and the quartz glass (see
(P)
drawing 2).
4 Fit the unit into the circuit using the 3-way connection
3-way connection is Ø 63 mm. If your pipes are smaller than 63 mm, you can use the
adapter (Ø 63 x Ø 50 mm)
. You can apply glue to the 3-way connection
(T)
side of the adapter
, there is a screw thread on the inside giving the option of fitting
(T)
a reduction piece, with a sealing ring (not included in the delivery), onto it if necessary.
5 Put the plug of the UVC device in a wall socket with a safety ground and fitted with
a residual current circuit-breaker. Check whether the lamp is operating by looking
through the transparent components of the unit. The unit is switched off by pulling
the plug out of the socket.
Installation of the dosing pump (Drawing 5&6, manual B)
1 Fit dosing tube A on nipple A, and dosing tube B, on nipple B. (see drawing 5)
2 Put the aspirator valve
in the can with dosing fluid. Ensure that this aspirator valve
(C)
is always situated at the bottom of the container.
3 Fix the injection valve
onto the injection point
(D)
takes place AFTER the water has passed the UV-lamp.
Instructions for use of the digital control panel
Important!
Never use an additional timer.
Always test the water yourself, the system will not do this for you.
The default factory settings of the UV-lamp and the dosing pump are set to "switched
off". The device will start operating after you have carried out all the settings.
First action before turning on the dosing pump (drawing 2, 5).
If the pump head has been stopped for a longer period of time, there is a risk that it
will stick. In this case, you will hear a clicking sound. This can be avoided by activating
the silicones in the pump head in advance by pulling the hose to and fro twice.
When the UVC lamp is switched on for the first time, or after a power failure, "tSet"
will appear on the display. This means the first thing you have to do is set the time. This
will always happen after the power has been turned off. Pressing the button
seconds will take you to the "tSet" menu, after that see drawing 12, manual B and read
the text "Setting the clock" on the next page.
Timer
The timer is set to the factory setting of 4,500 hours. The UVC lamp operates at 100%
radiation for up to 4,500 hours. After 4,500 hours, the radiation will weaken, and may
become insufficient to obtain the desired results.
If the UVC lamp had already been used previously, and is switched on again, "tSet" will
appear on the display and the time has to be set (see drawing 12, manual B and the
text "Setting the clock" on the next page. After that, the display will indicate the value
it had at the time it was switched off earlier. If you had increased or reduced the value
of the time meter yourself, the display will indicate the latest counter reading it had
before it was switched off.

Status overview

Drawing 7, manual B
The time of day (in 24-hour format) will be displayed by briefly pressing the button 1x.
By pressing the button shortly you will see the status of the dosing pump for every
hour of the day. After the dosing pump status you will see the status of the UV lamp
for every hour of the day.

Navigating through the menu

Drawing 8, manual B
Pressing the button for 1 x 3 seconds will take you to the main menu.
The main menu contains 4 control menus relating to the different applications. By
briefly pressing the button, you will be able to navigate through these various control
menus. As soon as you have reached the desired control menu, it can be selected by
again pressing the button for 3 seconds.
4
. The inlet and outlet of the
(I)
. On one
(I)
. Always ensure that the dosing
(F)
1 x 3
(R)
Hr:
setting the time meter of the lamp
dP:
adjusting dosing pump
Uv:
adjusting UV lamp
tSEt: adjusting the time
Key
press briefly
press for 3 sec.
10
do not do anything for 10 sec.
sec
selection confirmed
normal operating condition
lamp operating time (changeable)
time of day
lamp operating time
dosing pump
UV lamp
setting the timer
reset
increase
decrease
UV lamp on
UV lamp off
Setting the time meter of the lamp (Hr)
Drawing 9, manual B
In this position, the time meter can be reset, increased or decreased.
Pressing the button 1 x 3 seconds will take you to the main menu, where first Hr will
appear on the display.
By pressing the button once again for 3 seconds, you will enter the menu relating to
the operating hours of the lamp. The default value is set to 4,500 hours. If you wish,
the operating hours of the lamp can be modified in this menu by steps of 500 hours.
By pressing the button briefly in the Hr menu, it is possible to select between rSt, UP and
dn. One of these selections can be confirmed by again pressing the button for 3 seconds.
rSt:
This option will reset the meter indication to value 4,500 by keeping the
pushbutton down for 3 seconds. After this, the time meter will start counting
down again from the 4,500 hour value.
UP: By briefly pressing the pushbutton, the counter value can be increased from
4,500 in steps of 500 hours to a maximum value of 9999.
Ten seconds after the pushbutton has been released, the count-down from the
selected value will start.
dn: By briefly pressing the pushbutton, the counter value can be decreased from
4,500 in steps of 500 hours to a minimum value of 0000.
Ten seconds after the pushbutton has been released, the count-down from the
selected value will start.