Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting Procedure; Cleaning And Maintenance - RAVAK ESKK2 80 Montageanleitung

Runddusche zweiteilig
Vorschau ausblenden Andere Handbücher für ESKK2 80:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
ELEGANCE
The shower enclosure consists of:
Each part is packed separately. Assembly instructions, threshold strip, quick glue and drill are packaged with the
mounting kit for the left door ESKK2/L. Other accessories are packed separately for each part.
ATTENTION!
You will find the mounting kit inside the carton.
To mount this product in a finished bathroom, it is important to carefully measure and fix both parts of the shower
enclosure to the wall. You must also adjust the doors to their correct position and test their function, assemble the
door handles, drip sill and decorative caps. We reco mmend the assembly and installation be done by a trained
specialist from either our company, or from another installation firm.
FOR THIS PRODUCT TO FUNCTION PROPERLY IT SHOULD ONLY BE
INSTALLED ON STRONG WALLS.

MOUNTING PROCEDURE

1.
Check the size of the built-in shower tray. The distance from the wall to the top outer edge should be according to
the chart (
picture 1
). The shower tray must be level.
2.
Check the placement and layout of the doors. In the upper part of the door there are slots cut into the corners of
the glass. The upper part of the plastic post has an opening of 10 mm in diameter for the decorative cap.
3.
On the walls above the tray, mark the measurements from both directions . The position of the inner edge of the
mounting profile is determined by the perpendicular angle from these points (
distance between the outer edge of the superstructure and the edge of the tray should be 5 - 20 mm.
5.
Usingyourfingers,gentlypresstheedgeoftheplasticmoulding.Loosenandremoveitfromthemountingprofile(
4.
Unscrew the three M5 screws with washers and remove the mounting profile from the winged door (
picture 4
). Place the mounting profile onto the marked position on the tray,
then stand it up vertically and mark the oval opening of the mounting profile
on the wall (
picture 5
).
ATTENTION!
If the shower tray is not level, it is important that the
superstructure be placed perpendicular to the tray, and from this position it
can be fastened to the wall.
6.
Set aside the mounting profile. In the center of the marked oval,
drill a 10 mm diameter hole and place a dowel in it (
ATTENTION!
Watchoutforelectricalcablesandwaterandgasmainsinthewall!
7.
Fix the mounting profile to the wall using 5x50 mm bolts. Only lightly
tighten the bolts (picture 8).
8.
Mark and attach the other mounting profile in the same way.
9.
Attach the door to the mounting profile using M5 screws and washers.
Mount the other door in the same way.
10.
Use the slots and screws on the mounting profile to adjust the doors:
- on the edge of the tray where the doors touch each other, use a shim
(piece of wood) 18 - 20 mm in thickness, to rest the doors on;
- the doors must follow the shape of the tray;
- the doors must touch along their entire length so that the magnets can
hold them in the right position;
- the height of both doors must be the same, and the lower edge of the
glass must be level to the shower tray.
11.
After doing all of the adjustments, tighten the four visible bolts and the
three M5 screws on each mounting profile. Remove the shim and test the
function of the doors. Check the distance from the lower edge of the glass
to the shower tray with the enclosed gauge the (16.5 x 20 mm roller). The
clearance between the tray and the glass must be checked when the doors
are in the closed position, and should be between 16.5 and 18 mm.
12.
On the mounting profile outline the exact position of the adjusted doors.
From one door, unscrew the M5 screw which is holding it in place. Remove
the door and tighten the bolts inside the mounting profile. Place some
sealing compound on the bottom of the plastic door post (for mounting to
the shower tray). Place the plastic joint of the threshold strip into the slot in
the plastic post, with the higher side to the outside of the shower tray

CLEANING AND MAINTENANCE

ATTENTION!
Only use a soft cloth and normal household detergent for cleaning the lacquered surfaces, glass and plastic panels. Avoid using abrasive pastes, solvents,
acetones, etc.
We reco mmend the line of RAVAK ANTICALC products:
qualities of the RAVAK ANTICALC coating;
acrylic bathtubs, washbasins and water taps;
manufacturer is not responsible for damage caused by misuse, improper installation and repair of the product. The manufacturer has the right to constant
innovation and changes of the product.
The guarantee of the product is 24 months, only if the installation has been done by an authorized firm holding a certificate for Ravak products. In all other
cases, the guarantee time limit will be determined in accordance with the appropriate legal terms.
For further information concerning assembly, installation, and use and maintenance, please contact your local dealer.
Two part curved
shower enclosure
a left door ESKK2/L
a right door ESKK2/R
picture 6
).
RAVAK ANTICALC CONDITIONER
RAVAK CLEANER
worpcs to remove old and dried-on debris from glass surfaces, shower frames, enamel and
RAVAK DISINFECTANT
RAVAK a.s.,
Obecnická 285, 261 01 Příbram I, P. O. BOX 122
tel.: +420 318 427 200, 318 427 111 fax: +420 318 427 269
e-mail: smith@ravak.cz, www.ravak.com
ESKK2 80, 90, 100
n
picture 3
). At the same time, the
picture4
detailed in
(
picture 7
). Replace the doors in the exact marked position and tighten the
M5 screws. Do the same for the other shower door.
shower tray (
picture 7
and tighten the M5 screws. Do the same for the other shower door.
13.
Test the function of the doors several times and check the lifting
mechanism.
14.
Drill holes of 2.6 mm in diameter in the frame of the door according to
the pre-drilled holes in the mounting profile. Secure the frame using
3.5 x 13 mm self-tapping screws.
15.
Place one side of the plastic moulding into the mounting profile and
push slightly along the whole length to "lock" it into place (
16.
Test,andif necessary, adjusttheshapeandlength of the thresholdstrip sothat
thewholelengthofthebottomofthestripisincontactwiththeshowertray.
17.
Place the plastic joint of the threshold strip into the square slots on both
door posts.
18. Using quick glue, bead the bottom of the threshold strip along its entire length
(approximately200mm),andpointbypoint,glueittothetray(
19.
Place a small amount of sealing compound into the slots of the
threshold strip and completely seal it to the tray (picture 10).
20.
To complete the seal, put sealing compound on the seam between the
wall and the mounting profile, and along the outer side of the supporting
post to a height of 100 mm above the tray (
All joints and seals should be done with
compound which ensures a perfect cohesion of the plastics used.
21.
Fit the drip sill onto the bottom of the glass doors and test the function of
the doors. Adjust the drip sill if necessary (picture 13).
22.
Remove the drip sill and put quick glue on the entire surface of the cut
end. Re-mount the sill and push it into the original position. Glue the ends
to the posts and seal all the seams of the drip sill with sealing compound on
the bottom and sides and on the post (
23.
Put some silicon on the underside of the decorative cap and seat it on
the upper end of the plastic post (
24.
Mount the handles according to the instructions given with the product.
a preparation which perfectly renews and maintains all the
is a special preparation with notable anti-bacterial and anti-fungal effects. The
CONTENTS OF MOUNTING KIT
For right side ESKK2/R
1. Decorative cap No. 1
2. Right plastic drip sill
3. Plastic joint for threshold strip (right)
4. Dowel 10 mm diameter
5. Dowel bolt 5 x 50 mm diameter
6. Self-tapping screws 3.5x13 mm
7. RAVAK sealing compound
8. Washer 5 mm diameter
For left side ESKK2/L
1.
Decorative cap No. 1
2. Left plastic drip sill
3. Plastic joint for threshold strip (left)
4. Dowel 10 mm diameter
5. Dowel bolt 5x50 mm diameter
6. Self-tapping screws 3.5x13 mm
7. RAVAK sealing compound
8. Threshold strip
9. Quick glue 2 grams
10. Drill bit 2.6 mm diameter
11. Mounting instructions
12. Gauge 16 mm diameter
).
13. Washer 5 mm diameter
). Replace the doors in the exact marked position
picture 11
).
RAVAK PROFESSIONAL
picture 13
).
picture 14
).
1 pc
1 pc
1 pc
6 pcs
6 pcs
4 pcs
1 pc
6 pcs
1 pc
1 pc
1 pc
6 pcs
6 pcs
4 pcs
1 pc
1 pc
1 pc
1 pc
1 pc
1 pc
6 pcs
picture 9
).
picture1
0).
sealing
MN ESKK2 - 2/2003

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Eskk2 90Eskk2 100

Inhaltsverzeichnis