Start-up
Fill the equalizing tank with cooling liquid up the the level marking (B).
Attach the 4-pin HDD/CD drive power connector to the circulating pump (C) and
start up the computer. The pump is started up at the same time and fills the cooling
system with cooling liquid. Fill the equalizing tank again up to the level marking until
the liquid level is no longer seen to sink (D). Close the equalizing tank with the tank
lid (E / F).
TIP: To start up the pump without starting up the computer (to fill the wa-
ter cooling system), remove the ATX-connector from the mainboard, and
using an adapter that can be purchased separately (white connector with
wire loop), start the power supply by attaching the ATX-connector to the
connector. Do not operate the power supply units without any load.
Maintenance and care
If the circulating pump is started up properly according to these instructions, no
maintenance or care is necessary.
Waste disposal
Before discarding the circulating pump, empty any cooling liquid from the equalizing
tank.
CAUTION:
Heed any waste disposal regulations for the cooling liquid.
Technical information
The PCPS includes 4 programs to control the motor. The programs can be selected
by means of push-on jumpers (not included). The software is read out and activated
when the pump starts. To change the operating modes, proceed as follows: Remove
the lid from the motor body. This can be done without force and without tools.
Remove the lid by gently tipping it.
There are two push-on jumper fields at the top right of the board. To make changes,
arrange the jumpers as follows: