Herunterladen Diese Seite drucken

Packaging, Transport, Storage - CEMO UNI 750 l Bedienungsanleitung

Werbung

GB
Manufacture
1
Manufacturing requirements
1.1
PE inner container
(1) The containers must be manufactured in the same manufac-
turing facilities where the containers tested for the proof of
suitability were produced.
(2) It is permissible to fluorinate the container surface.
(3) If the blowing apparatus is changed (the extruder, blowing
head, or blowing mould, for example) the certification agency
is to be informed. They will then make a decision about how
to proceed (involving the DIBt, special tests).
1.2
Sheet steel bund (galvanized)
(1) The container must be manufactured according to the manu-
facturing description.
(2) Any change in manufacturing technology, material. or
sealant requires DIBt approval and changes to this General
Construction Inspection Approval.
2

Packaging, transport, storage

2.1
Packaging
Packaging the containers for the purpose of transport or (tem-
porary) storage is not necessary if the requirements of Sec. 2.2
are met. The openings of all connection muffs must be closed by
screwing on their caps.
2.2
Transport, storage
2.2.1 General instructions
Transport must be carried out by only those companies with
specialist experience, suitable machinery, equipment, and
means of transport, and sufficiently trained personnel. To avoid
hazards for employees and third parties, the applicable accident
prevention directives must be observed.
2.2.2 Transport preparation
The containers must be prepared for transport so that no dam-
age occurs during loading, transport, and unloading.
The loading surface of the transport vehicle must be constructed
so that it is not possible to damage the containers by impact or
pressure against a pointed object.
2.2.3 Loading and unloading
When lifting, moving, and setting down the containers, impact
loads must be avoided.
If a fork lift truck is used, the containers must be secured during
the moving with the fork lift.
Connection pieces and protruding parts of the containers may
not be used as lifting points for the containers. The containers
may not be dragged across a floor or the ground.
12
Annex 3, Sheet 1
of the General Construction Inspection
Approval no. Z-40.21-288,
August 24, 2006
2.2.4 Carriage
The containers must be secured against unacceptable shifts of
position during carriage.
The mode of fastening may not cause the containers to be
damaged.
2.2.5 Storage
When temporarily placed outside, the containers should be
protected against damage and storms. Containers must not be
exposed to weathering for more than six months.
2.2.6 Damage
When damages occur during transport or storage, the findings
of a water directives expert or the certification agency should be
followed.
Annex 3, Sheet 2
of the General Construction Inspection
Approval no. Z-40.21-288,
August 24, 2006

Werbung

loading

Diese Anleitung auch für:

Multi 750 lMulti 1000 lUni 1000 l