Version: x.x.x - The display shows the software version
installed on the device.
8.2 MENU – SETTINGS
Time – Function to set the clock.
Date – Function to set the date.
Language – Selection of available languages.
Main Parameters – Lists all the parameters that control
the basic machine functions. The basic settings are
protected with a lock code and should, if necessary, be
changed only by authorised personnel.
WC Auto Parameters – This lists all the parameters that
control the process of automatic water change, see
"Menu - Water Change". The basic settings are protected
with a lock code and should, if necessary, be changed
only by authorised personnel.
WC Manual Parameters – This lists all the parameters
that control the process of the manual (and final) part of
the water change, see "Menu - Water Change". The basic
settings are protected with a lock code and should, if
necessary, be changed only by authorised personnel.
8.3 MENU – WATER CHANGE
When the wheel washer is to undergo a change of
water, GP Filter eQ should be used for automatic
draining and filtration of the water (it is also
recommended to read through the sections dealing
with water change under "Seasonal Preventative
Maintenance").
Start – To immediately start an automatic water change -
confirm the selection and follow the instructions on the
display.
Manual – After an automatic water change described
above has been completed, some manual steps remain
before the process is complete - confirm the selection
and follow the instructions on the display.
Schedule – Scheduling when an automatic water change
should start.
8.4 MENU – SELF-TEST
The various sub-functions of the machine can be tested
in this menu. Testing is done manually and each self-test
function can be verified separately.
NOTE: Self-test cannot be performed when the unit is in
an active mode, i.e. during normal operation.
8
Drester GP Filter eQ
SELF-TEST
FUNCTION
Dosing Cylin-
der Valve
Bottom Cyl-
inder Valve
Drain pump
Blow Clean
Spare Relay
Mixing Valve
Vacuum
Pump Valve
Vessel Rinse
Valve
WW Water
Level
Water Level
Upper Vessel
Dosing Cylin-
der +
Dosing
Cylinder -
Bottom
Cylinder +
Bottom
Cylinder -
Door Sensor
Water Level
High
Vacuum
Sensor
Internal
Buzzer
NOTE: Apart from the self-test functions listed above,
there are also digital reserve inputs and reserve outputs
visible on the display. Ignore these during a self-test as
they are not linked to any function.
8.5 MENU – FACTORY RESET
Confirm the selection to restore the unit with factory
defaults.
NOTE: A factory reset will not reset the variables
"totflockcnt" and "totfiltercnt", see "Menu - Information"
under "User Interface".
EXPLANATION
TYPE
Moves dosing cylinder
Digital output
back and forth
Moves bottom cylinder up
Digital output
and down
Activates the drain pump
Digital output
(if installed on the unit)
Activates the blow function
Digital output
in front of the level sensor
in the upper vessel
Activates relay to clean
Digital output
rinsing function in the
wheel washer
Activates the blow function
Digital output
stirring water in the upper
vessel
Activates the vacuum func-
Digital output
tion in the upper vessel
Activates rinsing in the
Digital output
upper vessel
Indicates whether the level
Digital input
sensor in the level tube is
activated
Indicates whether the level
Digital input
sensor in the upper vessel
is activated
Indicates whether the dos-
Digital input
ing cylinder has completed
a stroke
Indicates whether the
Digital input
dosing cylinder is in home
position
Indicates whether the
Digital input
bottom cylinder is in home
position
Indicates whether the
Digital input
bottom cylinder has com-
pleted a stroke
Indicates whether the door
Digital input
is open/closed
Indicates the upper limit of
Analogue
the water level in the lower
input
vessel (if a drain pump is
installed on the unit)
Indicates the vacuum level
Analogue
in the upper vessel
input
Enables warning sounds
Ext.
(buzzer on circuit board)
231135 rev.3 2019-06-26
POS.
P22
P23
P24
P25
P26
P27
P28
P29
P11
P12
P13
P14
P15
P16
P21
P7:2
V51
BZ1