If you are using a MOTORCYCLE-SPECIFIC WIRING HARNESS,
-
follow the fitting instructions that come with it.
Before wiring, TAKE OFF THE POSITIVE BATTERY TERMINAL.
BLACK wire
N. 1
ORANGE wire
N. 2
RED wire
N. 3
BLUE wire
N. 4
YELLOW wires
N. 5
GREEN wires
N. 7
SPYBALL 6808-9/6828-9 ENGLISH
Negative power supply wire. Connect to a good earth
point. If the harness has got two negative power supply
wires, connect them to different earth points;
Ignition controlled positive supply wire (+15/54).
ALWAYS CONNECT. Make sure that the supply is also
live whilst the engine is cranking;
Positive power supply wire. Connect to a permanent
positive polarity via the 10A-fuse;
Instantaneous selectable (negative or positive) alarm
trigger input for (optional) contact switches, to be
installed – for example – for protection of the seat or of
the panniers. It can be connected also to the wire that
controls the lighting up of the original courtesy light in
the storage compartment under the seat. The polarity
selection procedure is described in paragraph 5;
Control outputs for turn indicators. Connect one to the
right line of the turn indicators (positive polarity), one to
the left line of the turn indicators (positive polarity);
First ignition immobilisation circuit. See application
diagram B.
While the engine is running, measure the value of
the electrical current in the circuit that has been
cut, to make sure that it does not exceed the
technical specifications of the product.
Install an additional relay if necessary.
6808 – 6809 = DO NOT USE;