ENGLISH

Designation of use:
Maximum static pressure:
Minimum working pressure:
Maximum working pressure
Recommended working pressure (hot &
cold):
Max hot water temperature:
Recommended hot water temperature:
Recommended cold water temperature:
Flow rate (bath):
Recommended maximum set mixed water temperatures
Application
Bath:
Shower:
Bath/Shower:
1. Valves operating outside these conditions of use cannot be guaranteed to operate as
Type 2 valves (intended operation not guaranteed).
2. The thermostatic mixer is pre-set to a safety stop temperature of 38 °C. Since operating
conditions in each supply system varies, it might be necessary to calibrate the mixer
according to the service and installation instructions.
3. You can override the safety stop temperature by pressing the override button.
4. The thermostatic mixer shall be verified against the original set temperature results
once a year according to the service and installation instructions.
5. If water supply is fed from a storage cistern by gravity then the supply pressure should
be verified to ensure the conditions of use are appropriate for the valve.
6. Hot and cold supply pressure should be balanced.

OPERATING CONDITIONS

HP (high pressure supply system)
10 bar (145 PSI)
0.5 bar (7.25 PSI)
10 bar (145 PSI)
1 – 5 bar (14.5 - 72.5 PSI)
80 ˚C / 176 ˚F
60 - 65 ˚C / 140 - 149 ˚F
10 - 15 ˚C/ 50 - 59 ˚F
20 l/min (5 gpm) @ 3 bar (43.5 PSI)
Maximum outlet temperature
46 °C / 115 ˚F
43 °C / 109.5 ˚F
43 °C / 109.5 ˚F
4