TECHNICAL SPECIFICATIONS

20A Model 220-240V - 50/ 60Hz operation
Primary input volts ..................................................... 220-240V AC 50/ 60Hz
Chlorinator power use ............................................... 250W
Maximum current draw .............................................. 10A
Pump outlet Max ....................................................... 8A
Cell volts .................................................................... 6-8V DC
Maximum cell current (above 20˚C) .......................... 20A DC
Degree of protection to AS1939 ................................ IP23
30A Model 220-240V - 50/ 60Hz operation
Primary input volts ..................................................... 220-240V AC 50/ 60Hz
Chlorinator power use ............................................... 375W
Maximum current draw .............................................. 10A
Pump outlet Max ....................................................... 8A
Cell volts .................................................................... 6-8V DC
Maximum cell current (above 20˚C) .......................... 30A DC
Degree of protection to AS1939 ................................ IP23
All units are equipped with a 3 Amps self-resetting fuse.

GENERAL SAFETY RULES

1. The equipment mentioned in this manual is specially designed for the sanitizing of water in swimming pools.
2. It is designed to work with clean water at a temperature not exceeding 35˚C ( 95˚F).
3. The installation should be carried out in accordance to the safety instructions of swimming pools especially
Standard HD 384.7.702 and the specific instructions for each facility.
4. The rules enforced on accident prevention should be carefully followed.
5. Any modification of the chlorinator requires the prior consent of the manufacturer. Original replacement parts
and accessories authorized by the manufacturer ensure a high level of safety. The manufacturer accepts no
liability for the damage and injuries caused by unauthorized replacement parts and accessories.
6. During operation, some parts of the chlorinator are subject to dangerous electric voltage. Work may only be
performed on the chlorinator or on the equipment connected to it after disconnecting them and the starting
device from the mains power.
7. The user should make sure that assembly and maintenance tasks are carried out by qualified authorized
persons and that these persons have first carefully read the Service and Installation Instructions.
8. The operating safety of the chlorinator is only guaranteed if the Installation and Service instructions are
correctly followed.
9. The limit values stated in the Technical Specifications should not be exceeded under any circumstance.
10. In the event of defective operation or fault, contact the manufacturer's Technical Support Department or
it's nearest Authorized Agent.
11. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person.
These chlorinators are approved and conformed to AS3136 Swimming Pool Equipment, as a prescribed article
under Australian Registration.
These chlorinators conform to the Australian Electromagnetic Compatibility Standard marked by the C-tick.