WATER CHEMISTRY

It is important to maintain the correct water chemical balance in the swimming pool; this will help protect the
Electrochlor chlorinator unit and its cell.
Consult the local pool professional for the correct water balance according to the swimming pool type.
The Electrochlor chlorinator will operate correctly at the following water chemistry levels :
pH.
Total alkalinity
Calcium hardness
Stabilizer (Sun screen)
Salt

FAULT TROUBLESHOOTING

SYMPTOM
Water sensing
LED will not
turn off
Low chlorine
level in pool
Chlorine production
LED reading low
Not all LEDs light
up when control
set at maximum
Unit does not
operate
60 - 200ppm
100 - 500ppm
5000 - 6500ppm
POSSIBLE CAUSE
Water flow restricted
Back washing in progress
Dirty flow detector
Electronic fault
Operating time too short
Production control too low
Low salt
Pool chemistry not correct
Chlorine production control
set too low
Low salt, water below 15˚C,
cell dirty or built-up.
Electrical fault
No electrical power
Pump not connected
Time clock setting
Electrical fault
7.2 - 7.8
Suggested 7.2 - 7.6
Suggested 80 - 150ppm
Suggested 60 - 250ppm
30 - 60ppm
Suggested 6000ppm
Empty leaf basket.
Clean filter.
Check water level.
Check all valves are open.
Change to normal filtration.
Clean flow detector.
Return to distributor for repair.
Increase operating time.
Turn control knob to increase production.
Add required amount of salt.
Have water tested.
Turn control knob to increase production.
Add salt, Increase water temp to 20˚C
and above. Clean cell.
Return to distributor for repair.
Connect power, check fuse.
Connect pump.
Reset clock.
Return to distributor for repair.
REMEDY