3.4
Relay
This relay output is closed under normal operation and is opened if
any or all of the following occurs:
• The unit looses power.
• A tamper alarm is triggered.
• There is an antenna failure.
The relay output is open during boot up, which normally takes
approx. 1 second and is closed when the unit has booted up and
runs normally.
3.5
Setting position ID code
Each D-POS unit must be identified with a unique code and is
composed as the hexadecimal value "00S1S2" (ZeroZeroS1S2), where
0000 (four zeroes) is forbidden. With the on-board rotary switches S1
and S2 it is possible to assign one of 255 valid position ID codes.
To set position ID codes and zone ID DIP 1 must be set to OFF.
Example: Setting S1 to "7" and S2 to "B" gives the position ID code
007B (ZeroZero7B).
3.6
Setting zone ID
Each D-POS unit must be configured to belong to one of 16 zones:
0-F (hexadecimal) and this is determined by rotary switch S3.
3.7
LED Indication
During normal operation the LED is lit green and when the D-POS II
unit is powered up the LED flashes (0.1s On/0.1s Off) yellow twice.
LED Colour
Red
Green (2.0s on/1.0 off)
Red flash (0.5s on/0.5s off )
Red
Green
Off
Table 4. D-POS II LED indications
D-POS II - NE41 17028-00 v1.0
Function
Radio transmission in progress.
Acknowledment received.
Tamper or antenna failure.
Relay active due to received radio message.
Normal operation (RFID is emitted).
Waiting for external activation.
7